非原厂钛基座粘接饰面氧化锆基台的前瞻性病例系列1年结果
1年随访显示探诊深度和探诊出血显著增加,种植体存活率95.8%,16.7%种植体诊断为种植体周围炎。
要点
- 非原厂钛基座粘接饰面氧化锆修复体1年存活率95.8%,4颗种植体(16.7%)诊断种植体周围炎。
- 探诊深度从基线3.0±0.6 mm增至1年3.5±0.7 mm(p=0.002),探诊出血从27.1%±20.7%增至43.9%±28.0%(p=0.041)。
- 技术并发症发生4例,无并发症修复体比例为83.3%。
核心结论
- 使用非原厂钛基座粘接直接饰面氧化锆修复体后,探诊深度和探诊出血值显著增加。
主要发现
- 平均边缘骨水平基线为0.54±0.39 mm(中位数0.47,范围0.07-1.75 mm),1年时为0.54±0.45 mm(中位数0.44,范围0.06-1.52 mm)。
- 探诊深度从基线3.0±0.6 mm增至1年3.5±0.7 mm(p=0.002)。
- 探诊出血从基线27.1%±20.7%增至1年43.9%±28.0%(p=0.041)。
- 菌斑指数从基线11.1%±21.2%增至1年18.2%±21.8%(p=0.381),角化黏膜宽度从基线3.1±1.3 mm降至1年3.0±1.2 mm(p=0.398)。
- 4颗种植体(16.7%)在1年观察期内诊断为种植体周围炎(探诊出血阳性,骨丧失>1 mm);1颗种植体在3个半月时脱落,存活率95.8%;发生4例技术并发症,无并发症修复体比例为83.3%。
临床怎么用
- 使用非原厂钛基座粘接饰面氧化锆修复体时,需在1年内密切监测探诊深度和探诊出血变化。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: To assess clinical, technical, and esthetic outcomes of veneered zirconia reconstructions cemented on non-original titanium bases over 1 year. MATERIALS AND METHODS: Twenty-four healthy patients presented with one missing tooth in the anterior maxilla or mandible and received a two-piece dental implant. The implants were restored with a screw-retained crown using a directly veneered zirconia reconstruction, which was extraorally cemented on a titanium base. After crown insertion, patients were scheduled for a baseline examination and re-examined at 6 months and at 1 year of loading. Measurements included biological, technical, and esthetic parameters. Data were analyzed with nonparametric tests. RESULTS: Mean marginal bone levels measured 0.54 ± 0.39 mm (median: 0.47, range: 0.07-1.75 mm) at baseline and 0.54 ± 0.45 mm (median: 0.44, range: 0.06-1.52 mm) at 1 year. Mean probing depth (PD) (3.0 ± 0.6 mm at baseline to 3.5 ± 0.7 mm at 1 year [p = 0.002]), bleeding on probing (BOP) (27.1% ± 20.7% at baseline to 43.9% ± 28.0% at 1 year [p = 0.041]), plaque index (PI) (11.1% ± 21.2% at baseline to 18.2% ± 21.8% at 1 year [p = 0.381]) increased, whereas the width of the keratinized mucosa decreased from baseline to 1 year (3.1 ± 1.3 mm at baseline to 3.0 ± 1.2 mm at 1 year [p = 0.398]). Four implants (16.7%) were diagnosed with peri-implantitis (BOP positive, bone loss >1 mm) during the 1-year observation period. One implant was lost at 3 ½ months, resulting in a 95.8% survival rate. Four technical complications occurred and led to 83.3% complication-free reconstructions. CONCLUSION: A significant increase in PD and BOP values was observed using directly veneered zirconia reconstructions cemented on non-original titanium bases.
引用
- Asgeirsson AG, Sailer I, Gamper F, et al. Veneered zirconia abutments cemented on non-original titanium bases: 1-year results of a prospective case series. Clin Oral Implants Res. 2019. PMID: 31102476. doi:10.1111/clr.13457
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。