文献速递口腔修复与种植

种植体支持单冠的回顾性临床评估:平均随访15年

Retrospective clinical evaluation of implant-supported single crowns: Mean follow-up of 15 years.
PubMed 文献 · Clin Oral Implants Res · 2019-05-17

这项回顾性研究纳入单中心的438例患者共567颗种植体支持单冠,平均随访183.4±69.3个月。37颗种植体(6.5%)和54颗冠(9.5%)失败,仅计技术问题时冠失败率降至4.1%(23/567)。年轻患者、上颌冠和螺丝固位冠的冠失败几率显著更高。

要点

  • 种植体支持单冠平均随访15年,冠失败率9.5%、种植体失败率6.5%。
  • 仅计技术性并发症时冠失败率为4.1%,非技术性原因同样常见。
  • 年轻患者、上颌冠、螺丝固位冠的冠失败几率显著更高。

核心结论

  • 部分因素与种植体支持单冠的冠失败几率显著相关,但非技术性并发症与技术性并发症作为冠更换原因同样常见。

研究设计与样本

  • 回顾性研究,纳入单中心所有接受种植体支持单冠治疗的患者,共438例患者、567颗冠,平均随访183.4±69.3个月。

主要发现

  • 37颗种植体(6.5%)和54颗冠(9.5%)失败;仅计技术问题时冠失败率为4.1%(23/567)。
  • 冠失败最常见原因依次为美学问题(n=12)、冠持续松动(n=9)、与其他种植体一起更换为另一类型修复体(n=8)、冠折裂(n=7)、冠相较于邻牙低位(n=7)。
  • 年轻患者、上颌冠和螺丝固位冠的冠失败几率显著更高。
  • 修复螺丝松动在螺丝固位冠中远比粘接冠常见;瓷崩裂/折裂在螺丝固位冠、上颌、女性中更常见;冠折裂在全瓷冠、螺丝固位冠、上颌、后牙区、女性中更常见,但仅女性冠折裂差异有统计学显著性。

临床怎么用

  • 对年轻患者、上颌单冠及螺丝固位单冠应加强随访,关注冠失败及非技术性并发症风险。
  • 螺丝固位冠需重点监测修复螺丝松动和瓷崩裂/折裂。

局限性

  • 回顾性设计,单中心数据,可能存在选择偏倚和记录不完整。
  • 部分并发症的组间差异未达统计学显著性,需谨慎解读。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To retrospectively assess the clinical outcomes of implant-supported single crowns and the supporting implants. MATERIAL AND METHODS: This retrospective study included all patients treated with implant-supported single crowns at one specialist clinic. Implant and prosthesis failure, and mechanical/technical complications (ceramic fracture/chipping; crown loss of retention/mobility; crown failure/fracture; loosening/loss/fracture of prosthetic screw; and implant failure/fracture) were the outcomes analyzed. Any condition/situation that led to the removal/replacement of crowns was considered prosthesis failure. RESULTS: A total of 438 patients with 567 crowns were included. Mean ± SD follow-up of 183.4 ± 69.3 months. A total of 37 implants (6.5%) and 54 crowns (9.5%) failed. If only technical problems were considered, the crown failure rate decreased to 4.1% (23/567). Most common reasons for crown failure: esthetic issue (n = 12), crown constantly mobile (n = 9), change to another type of prosthesis together with other implants (n = 8), crown fracture (n = 7), and crown in infraposition in comparison with adjacent teeth (n = 7). The odds of crown failure were shown to be statistically significantly higher for the following factors: younger patients, maxillary crowns, and screw-retained crowns. Loose prosthetic screw was much more prevalent in screw-retained than in cemented crowns. Ceramic fracture/chipping was more prevalent in screw-retained crowns, maxillae, females. Crown fracture was more prevalent in ceramic crowns, screw-retained crowns, maxillae, posterior region, females. However, these differences were statistically significant only for crown fractures in females. CONCLUSIONS: The odds of crown failure were significant for some factors, but one must keep in mind that non-technical complications are as common as technical ones as reasons for the replacement of implant-supported single crowns.

来源:Clin Oral Implants Res,查看原文。版权归原作者所有。

引用

  1. Chrcanovic BR, Kisch J, Larsson C, et al. Retrospective clinical evaluation of implant-supported single crowns: Mean follow-up of 15 years. Clin Oral Implants Res. 2019. PMID: 31066937. doi:10.1111/clr.13454

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。