文献速递牙体牙髓病

不同工作长度下两种往复系统在弯曲根管中碎屑挤出比较

Extrusion of Debris from Curved Root Canals Instrumented up to Different Working Lengths Using Different Reciprocating Systems.
PubMed 文献 · J Endod · 2019-05-17

INTRODUCTION: The aim of this study was to evaluate the extrusion of debris associated with the use of the Reciproc (VDW GmbH, Munich, Germany) and WaveOne Gold (Dentsply Maillefer, Ballaigues, Switzerland) reciprocating systems in curved canals instrumented up to different worki…

要点

  • Reciproc与WaveOne Gold在弯曲根管中根尖碎屑挤出量无显著差异。
  • 工作长度达根尖孔或短1mm对碎屑挤出量无显著影响。
  • 研究采用离体牙模型,临床决策需结合其他因素。

核心结论

  • 两种往复系统在弯曲根管中根尖碎屑挤出量相似,与所用工作长度无关。

主要发现

  • 四组间碎屑挤出量无统计学显著差异(P>.05)。

关键数值与推荐

  • 纳入根管弯曲度10°至20°且根尖孔独立。
  • 工作长度设为根尖孔处或短1mm。
  • 冲洗液为双蒸水。

临床怎么用

  • 在弯曲根管预备中,两种往复系统及工作长度选择对碎屑挤出影响相似。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: The aim of this study was to evaluate the extrusion of debris associated with the use of the Reciproc (VDW GmbH, Munich, Germany) and WaveOne Gold (Dentsply Maillefer, Ballaigues, Switzerland) reciprocating systems in curved canals instrumented up to different working lengths (WLs). METHODS: Sixty mesial roots of extracted mandibular first molars with mesiobuccal canals having curvatures between 10° and 20° and independent foramina were randomly distributed into 4 experimental groups (n = 15) according to WL and the instrumentation system used: RC0, Reciproc and WL at the apical foramen; RC1, Reciproc and WL at 1 mm short of the apical foramen; WOG0, WaveOne Gold and WL at the apical foramen; and WOG1, WaveOne Gold and WL at 1 mm short of the apical foramen. The canals were irrigated with double-distilled water throughout the preparation. Each root was fit into an Eppendorf tube to collect the debris extruded through the foramen during instrumentation. After instrumentation, the roots were removed from the tubes, and the weight of the debris was obtained by subtracting the initial weight of the tubes from their final weight. The data were submitted to the analysis of variance parametric test complemented by the Tukey test. RESULTS: No statistically significant difference was observed between the 4 experimental groups regarding the amount of debris extruded (P > .05). CONCLUSIONS: The 2 reciprocating systems tested were associated with similar amounts of apically extruded debris, regardless of the working length used in the instrumentation.

来源:J Endod,查看原文。版权归原作者所有。

引用

  1. Mendonça de Moura JD, Bueno CEDS, Fontana CE, et al. Extrusion of Debris from Curved Root Canals Instrumented up to Different Working Lengths Using Different Reciprocating Systems. J Endod. 2019. PMID: 31109752. doi:10.1016/j.joen.2019.03.002

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。