文献速递牙体牙髓病

两种根管预备系统与两种声波冲洗装置清除下颌磨牙远中根管充填材料的微CT评价

Evaluation of two shaping systems and two sonic irrigation devices in removing root canal filling material from distal roots of mandibular molars assessed by micro CT.
PubMed 文献 · Int Endod J · 2019-06-17

本研究以40颗离体下颌磨牙远中椭圆根管为对象,比较Reciproc与2Shape两种再治疗预备系统清除根充物的效果,并评估MM1500与Eddy两种声波冲洗装置的辅助作用。微CT显示两系统整体清除率无显著差异,声波激活可显著降低残留充填物体积。

要点

  • Reciproc与2Shape清除根充物整体效果无显著差异(P=0.355)。
  • 2Shape与Reciproc分别清除95.8%和94.0%的初始充填物体积。

核心结论

  • 下颌磨牙远中椭圆根管再治疗中,2Shape与Reciproc清除牙胶/封闭剂的效果无显著差异。
  • MM1500和Eddy声波激活可显著改善充填材料的清除。

研究设计与样本

  • 离体牙实验:40颗离体下颌磨牙远中根管经ProTaper Next预备、Gutta Percha X2与AH Plus充填后随机分为Reciproc组和2Shape组(n=20)。
  • 再治疗前后及声波冲洗后共进行三次微CT扫描评估充填物残留体积。
  • 统计采用Wilcoxon符号秩检验、Mann-Whitney检验和Kruskal-Wallis检验。

主要发现

  • Reciproc与2Shape清除充填物体积在全根管水平无显著差异(P=0.355)。
  • 2Shape组充填物体积从4.71 mm3降至0.22 mm3,降幅95.8%(P<0.001)。
  • Reciproc组充填物体积从5.05 mm3降至0.33 mm3,降幅94.0%(P<0.001)。
  • 声波激活使残留充填物体积分别额外降低3.21%(P=0.013)、1.38%(P=0.012)、1.83%(P=0.008)和1.83%(P=0.012)。
  • 最终各组全根管残留材料百分比无显著差异(P=0.163)。

关键数值与推荐

  • 2Shape清除95.8%初始充填物体积(从4.71降至0.22 mm3,P<0.001)。
  • Reciproc清除94.0%初始充填物体积(从5.05降至0.33 mm3,P<0.001)。
  • 声波激活后残留体积降低:第一组3.21%(P=0.013)、第二组1.38%(P=0.012)、第三组1.83%(P=0.008)、第四组1.83%(P=0.012)。

临床怎么用

  • 再治疗清除下颌磨牙远中椭圆根管充填物时,2Shape与Reciproc均可作为有效预备系统。
  • 在机械预备后辅以MM1500或Eddy声波冲洗,有助于进一步减少根充物残留。

局限性

  • 研究为离体牙实验,结果需结合临床情况判断。
  • 仅评估下颌磨牙远中椭圆根管,结论不直接适用于其他根管类型。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIM: To compare two preparation systems and two sonic irrigation devices during the removal of root filling material from oval distal canals of extracted mandibular molars. METHODOLOGY: The distal canals in 40 extracted mandibular molars were shaped using the ProTaper Next system (Dentslpy Sirona, Ballaigues, Switzerland), filled with Gutta Percha X2 (Dentsply Sirona), along with AH Plus sealer (Dentsply De Trey, Konstanz, Germany) and randomly divided into two groups (n = 20) according to volume of initial filling, preparation diameter and working length. One group was retreated using the Reciproc system (VDW, Munich, Germany), and the other using the 2Shape system (Micro-Mega, Besançon, France). A micro-CT scan was taken after the initial root filling and after retreatment to evaluate the volume of filling material remnants. The teeth were divided into four groups to test the supplementary effect of two sonic irrigation devices on removing filling material: Eddy (VDW) and MM1500 (Micro-Mega). In the first and second groups, 2Shape was followed subsequently by MM1500 and Eddy; in the third and fourth groups, Reciproc was followed by MM1500 and Eddy. A third micro-CT was taken to compare the remaining root filling material in all groups. Wilcoxon's signed rank tests, Mann-Whitney and Kruskal-Wallis tests were used for statistical analysis. RESULTS: No significant difference was found for the volume of filling material removed between the Reciproc and 2Shape in the entire canal (P = 0.355). The volume dropped significantly from its initial value after removing the bulk of the root filling by 95.8% (from 4.71 to 0.22 mm3 ) with the 2Shape (P < 0.001) and by 94.0% (from 5.05 to 0.33 mm3 ) with the Reciproc (P < 0.001). Sonic activation significantly decreased the residual volume of filling material remnants by 3.21% (P = 0.013) in the first group, 1.38% (P = 0.012) in the second group, 1.83% (P = 0.008) in the third group and 1.83% (P = 0.012) in the fourth group. At the end, the percentage of residual material was not significantly different among the groups in the entire canal (P = 0.163). CONCLUSION: In the distal oval canals of extracted mandibular molar teeth, there was no significant difference between the 2Shape and Reciproc systems in removing gutta-percha/sealer. Sonic activation with MM1500 and Eddy significantly improved filling material removal.

来源:Int Endod J,查看原文。版权归原作者所有。