三种补充冲洗方案去除下颌磨牙近中根管系统硬组织碎屑的疗效
研究用微型CT评估三种补充冲洗系统(间歇超声、连续超声、GentleWave)对下颌磨牙近中根管系统硬组织碎屑的去除效果。
要点
- GentleWave去除根管和峡部硬组织碎屑的效率显著高于连续超声。
- 间歇超声与GentleWave及连续超声的碎屑减少率均无显著差异。
- 连续超声与间歇超声的碎屑去除效果相当。
核心结论
- GentleWave在去除下颌磨牙近中根管系统硬组织碎屑方面优于连续超声,但与间歇超声无显著差异。
- 连续超声与间歇超声的碎屑去除效果相当。
研究设计与样本
- 使用WaveOne Gold器械预备后,按解剖匹配分为3组(每组8颗),分别采用间歇超声、连续超声和GentleWave进行最终冲洗。
- 冲洗前后以17.18微米像素尺寸进行微型CT扫描,计算根管和峡部硬组织碎屑减少百分比,采用单因素方差分析和Tukey事后检验(显著性水平5%)。
主要发现
- 根管和峡部硬组织碎屑平均减少百分比:GentleWave为96.4%和97.9%,连续超声为80.0%和88.9%,间歇超声为91.2%和93.5%。
- GentleWave的碎屑减少率显著高于连续超声(P < .05)。
- 间歇超声的碎屑减少率与GentleWave和连续超声均无显著差异(P > .05)。
临床怎么用
- 对于下颌磨牙近中根管系统,GentleWave可能比连续超声更有效地去除峡部硬组织碎屑。
- 间歇超声可作为与GentleWave效果相当的补充冲洗选择。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: Instrumentation of the mesial root canal system of mandibular molars may hinder disinfection by packing hard tissue debris within the isthmuses. The removal of accumulated hard tissue debris (AHTD) by 3 supplemental irrigation systems, 2 ultrasonically activated and 1 multisonic, was assessed with micro-computed tomographic imaging. METHODS: Twenty-four extracted mandibular molars with 2 mesial canals connected by an isthmus and converging to a single foramen were selected. After preparation of the mesial canals with WaveOne Gold instruments (Dentsply Maillefer, Ballaigues, Switzerland), anatomically matched specimens were assigned to 3 final irrigation protocols (n = 8): intermittent ultrasonic (IU) with an ultrasonically energized 200-μm wire (Irrisafe; Satelec, Bordeaux, France), continuous ultrasonic (CU) with an ultrasonic irrigation needle (ProUltra PiezoFlow, Dentsply Maillefer), and GentleWave (GW) system (Sonendo Inc, Laguna Hills, CA). Specimens were scanned (SkyScan 1176; Bruker-microCT, Kontich, Belgium) at 17.18-μm pixel size before and after preparation and irrigation protocols. Data sets were coregistered, and the percentage reduction of AHTD calculated within the canals and isthmus for each specimen was statistically compared using 1-way analysis of variance and post hoc Tukey tests with a 5% significance level. RESULTS: The mean percentage reduction of AHTD in canals and isthmuses was significantly higher for GW (96.4% and 97.9%, respectively) than for CU (80.0% and 88.9%, respectively) (P < .05). AHTD reduction for IU (91.2% and 93.5%, respectively) did not differ significantly from GW and CU (P > .05). CONCLUSIONS: GW achieved greater efficacy in the removal of AHTD from the mesial root canal system of mandibular molars compared with CU but not IU. The efficacy of CU and IU was comparable.
引用
- Chan R, Versiani MA, Friedman S, et al. Efficacy of 3 Supplementary Irrigation Protocols in the Removal of Hard Tissue Debris from the Mesial Root Canal System of Mandibular Molars. J Endod. 2019. PMID: 31104820. doi:10.1016/j.joen.2019.03.013
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。