不同种植冠设计配合邻间清洁工具去除模拟生物膜的体外研究
本体外研究比较两种种植支持修复体设计(传统冠设计CCD与替代冠设计ACD)配合五种邻间清洁工具去除模拟生物膜的效果。30名受试者(牙医、洁牙士和非专业人士)对下颌模型上的种植冠进行清洁,结果显示ACD在超级牙线、牙线和牙间刷下清洁率均高于CCD,超级牙线效率最高(ACD 76±13%,CCD 57±14%),但任何组均无法完全去除模拟生物膜。
要点
- ACD在超级牙线、牙线和牙间刷下清洁率均高于CCD。
- 超级牙线清洁效率最高,微滴牙线最低。
- 任何工具均无法完全去除模拟生物膜。
核心结论
- 替代冠设计(ACD)在超级牙线、牙线和牙间刷下比传统冠设计(CCD)去除更多模拟生物膜。
研究设计与样本
- 体外研究,下颌模型单颗种植类似物,两种冠设计,30名受试者(牙医、洁牙士和非专业人士各10名)使用五种清洁工具。
主要发现
- 超级牙线清洁率:ACD 76±13%,CCD 57±14%。
- 牙线清洁率:ACD 66±13%,CCD 56±15%。
- 牙间刷清洁率:ACD 55±10%,CCD 45±9%。
- 电动间隙刷清洁率:ACD 31±10%,CCD 30±1%。
- 微滴牙线清洁率:ACD 8±9%,CCD 9±8%。
关键数值与推荐
- 清洁工具、表面、冠设计和受试者类型均对清洁率有整体效应(p < 0.0001)。
临床怎么用
- 临床可优先选用超级牙线、牙线或牙间刷清洁种植冠邻间区域。
- ACD设计可能更利于邻间清洁,但需结合患者情况选择。
局限性
- 体外研究使用模拟生物膜,结果不能直接等同于临床实际。
- 受试者包含非专业人士,可能影响清洁效果的普遍性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: To compare the removal of simulated biofilm at two different implant-supported restoration designs with various interproximal oral hygiene aids. METHODS: Mandibular models with a missing first molar were fabricated and provided with single implant analogues (centrally or distally placed) and two different crown designs (conventional [CCD] and alternative crown design [ACD]). Occlusion spray was applied to the crowns to simulate artificial biofilm. Thirty participants (dentists, dental hygienists, and laypersons) were equally divided and asked to clean the interproximal areas with five different cleaning devices to further evaluate if there were differences in their cleaning ability. The outcome was measured via standardized photos and the cleaning ratio, representing the cleaned surfaces in relation to the respective crown surface. Statistical analysis was performed by linear mixed-effects model with fixed effects for cleaning tools, surfaces, crown design and type of participant, and random effects for crowns. RESULTS: The mean cleaning ratio for the investigated tools and crown designs were (in%): Super floss: 76 ± 13/ACD and 57 ± 14/CCD (highest cleaning efficiency), followed by dental floss: 66 ± 13/ACD and 56 ± 15/CCD, interdental brush: 55 ± 10/ACD and 45 ± 9/CCD, electric interspace brush: 31 ± 10/ACD and 30 ± 1/CCD, microdroplet floss: 8 ± 9/ACD and 9 ± 8/CCD. There was evidence of an overall effect of each factor "cleaning tool," "surface," "crown design," and "participant" (p < 0.0001). CONCLUSIONS: ACD allowed more removal of the artificial biofilm than CCD with Super floss, dental floss, and interdental brush. Flossing and interproximal brushing were the most effective cleaning methods. A complete removal of the artificial biofilm could not be achieved in any group.
引用
- Tuna T, Kuhlmann L, Bishti S, et al. Removal of simulated biofilm at different implant crown designs with interproximal oral hygiene aids: An in vitro study. Clin Oral Implants Res. 2019. PMID: 31033028. doi:10.1111/clr.13448
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。