角化黏膜宽度与种植体周围黏膜炎严重程度相关:横断面研究
非调整分析显示KM不足2mm与种植体周围黏膜炎显著相关(OR 3.3,95%CI 1.3-8.0,p=0.009)且与疾病严重程度相关(均差2.5,95%CI 0.8-4.2,p=0.004)。结论认为KM不足是种植体周围黏膜炎严重程度的风险指标。
要点
- KM宽度不足2mm与种植体周围黏膜炎显著相关(OR 3.3)
- KM不足与黏膜炎严重程度相关(均差2.5)
- 充足KM可能有助于降低黏膜炎风险及严重程度
核心结论
- 角化黏膜宽度减少是种植体周围黏膜炎严重程度的风险指标。
- 总体趋势表明充足的角化黏膜可能有助于降低种植体周围黏膜炎的风险和严重程度。
研究设计与样本
- 临床测量角化黏膜宽度、菌斑指数、牙龈指数、探诊出血指数和探诊深度。
- KM不足定义为宽度低于2mm和1mm;主要分析采用广义估计方程(GEE)模型在种植体水平分析,敏感性分析采用调整线性混合模型。
主要发现
- 非调整种植体水平分析中,KM减少与种植体周围黏膜炎显著相关(OR 3.3,95%CI 1.3-8.0,p=0.009)。
- 非调整分析中KM减少与疾病严重程度显著相关(均差2.5,95%CI 0.8-4.2,p=0.004)。
- 敏感性分析中KM减少与疾病严重程度显著相关(OR 1.7,95%CI 0.1-34,p=0.040)。
临床怎么用
- 临床评估种植体周围组织时应关注角化黏膜宽度。
- KM不足2mm的种植体可能需更密切监测黏膜炎严重程度。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: This is a cross-sectional study designed with the aim to assess associations between the width of keratinized tissue and peri-implant mucositis. MATERIALS AND METHODS: Two hundred and thirty one dental implants in 52 patients were evaluated. The width of keratinized mucosa (KM), plaque index (mPI), gingival index (mGI), bleeding on probing index (BoP), and the probing depth (PD) were measured clinically. Reduced KM was defined as a width of KM below 2 mm and 1 mm, respectively. In the primary analysis, data were analyzed on the implant level with the help of a generalized estimating equations (GEE) model. In sensitivity analyses, an adjusted linear mixed model was performed. RESULTS: Forty four implants in 12 patients had less than 2 mm KM, and 187 implants in 40 patients had ≥ 2 mm KM. In the non-adjusted analysis on the implant level, reduced keratinized tissue width was significantly associated with peri-implant mucositis (OR 3.3, 95%-CI (1.3-8.0), p = 0.009) and severity of disease (mean difference 2.5, 95%-CI (0.8-4.2) p = 0.004). In sensitivity analyses, reduced keratinized tissue showed a significant association with severity of disease (OR 1.7, 95%-confidence interval = 0.1-34, p = 0.040). CONCLUSION: A reduced width of keratinized tissue around dental implants is a risk indicator for severity of peri-implant mucositis. The overall tendency of the results indicates that a sufficient amount of KM may contribute to reduce risk for and severity of peri-implant mucositis.
引用
- Grischke J, Karch A, Wenzlaff A, et al. Keratinized mucosa width is associated with severity of peri-implant mucositis. A cross-sectional study. Clin Oral Implants Res. 2019. PMID: 30972785. doi:10.1111/clr.13432
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。