文献速递牙体牙髓病

根管中三分之一分离锉取出对牙根抗垂直折裂性能影响的三维有限元分析

[Impact of fractured file removal from the middle third root canal on vertical root fracture resistance: three-dimensional finite element analysis].
PubMed 文献 · Zhonghua Kou Qiang Yi Xue Za Zhi · 2019-01-01

该研究通过三维有限元法分析超声取出根管中三分之一分离锉对牙根抗折力的影响。取锉样本最大抗压载荷为406 N(模拟396 N),对照为502 N(模拟483 N);取锉后应力集中于棱角、裂纹多且扩展快,抗折力明显下降。结论建议减少牙本质切削并将棱角修整圆滑。

要点

  • 取分离锉后牙根最大抗压载荷由502 N降至406 N。
  • 取锉后根管棱角处应力集中严重,裂纹条数增多。
  • 临床应尽量减少牙本质切削并将棱角修整圆滑。

核心结论

  • 取根管中三分之一分离锉会明显降低牙根整体抗折力。
  • 取锉时应尽量减少牙本质切削并将根管壁棱角修整圆滑以减少应力集中。

研究设计与样本

  • 建立取分离锉模型(超声取出后根管预备)与对照模型(仅根管预备)的三维有限元模型。
  • 将有限元计算结果与牙根抗压载荷实验数据对比验证模型有效性。
  • 在验证后的模型上比较裂纹产生、扩展、裂开时的应力分布差异。

主要发现

  • 取分离锉样本牙根最大抗压载荷为406 N,有限元模拟结果为396 N。
  • 对照样本牙根最大抗压载荷为502 N,有限元模拟结果为483 N。
  • 有限元仿真的裂纹萌生位置与实验基本一致。
  • 对照样本应力分布均匀,裂纹萌生与扩展方向有一定不可预测性。
  • 取锉样本根管棱角处应力集中严重、裂纹条数多、根管壁薄且裂纹扩展快。

临床怎么用

  • 取分离锉过程中应尽量减少牙本质切削。
  • 将取锉造成的根管壁棱角修整圆滑以降低应力集中和牙根折裂风险。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Objective: To analyze effect of fractured file removal from the middle third root canal on root fracture resistance using finite element analysis, which provides a theoretical basis for clinical prognosis evaluation. Methods: Two finite-element models were established, the fractured file removal model (fractured file located in the middle third of root canals, followed by ultrasonic file removal and root canal preparation) and the control model (root canal preparation only), and compressive displacement dependencies on compressive force was computed and compared with experimental data for validation. The validated finite-element models were used to analyze the stress distribution differences during the initiation, propagation and completion of the crack between fractured file removal specimen and control one. Results: The critical breaking force of the fractured file removal specimen was 406 N, and the finite element simulation result was 396 N. The critical breaking force of the control specimen was 502 N, and the finite element simulation result was 483 N. The position of crack initiation in the finite element simulation was basically consistent with that in the experiment. The experimental data of compressive test and the results of finite-element computation were in agreement, thus validating the finite-element model. In the process of continuous pressure, the stress distribution of the control root is relatively uniform, and the location of crack initiation and the direction of propagation have a certain unpredictability. Compared with the control root, the stress concentration on the root with fracture file removal was obvious, especially on edges, and the number of cracks are much more. Because of the thinner radicular wall, the crack propagation rate is faster too. Therefore, the overall root fracture resistant is decreased obviously. Conclusions: During the fractured file removal procedure, amount of dentine removed should be minimized, and the edges and corners which caused by fractured file removal should be shaped to smooth in order to reduce the stress concentration and prevent the root from fracture. 目的: 采用有限元法分析超声法取根管中部分离根管锉对牙根抗力的影响,为临床评估预后提供依据。 方法: 构建取分离根管锉样本(根管锉分离于根管中部,超声法取出后根管预备)及对照样本(仅进行根管预备)的三维有限元模型,在有限元模型上模拟牙根抗压载荷实验过程,将有限元计算结果与实验结果进行对比,验证有限元模型的准确性。在验证后的有限元模型上,比较分析取分离根管锉样本及对照样本的根管壁裂纹产生、扩展、裂开时的应力变化差异。 结果: 取分离根管锉样本,牙根最大抗压载荷为406 N,有限元模拟结果为396 N;对照样本牙根最大抗压载荷为502 N,有限元模拟结果为483 N。有限元仿真的裂纹萌生位置与实验基本一致。有限元模拟结果与实验测试结果一致,验证了有限元模型的有效性。对照样本应力分布均匀,裂纹萌生、扩展的方向均有一定的不可预测性。取分离根管锉样本的根管棱角处应力集中严重,裂纹产生条数多;根管壁薄,裂纹扩展速度快,牙根整体抗折力明显下降。 结论: 取分离根管锉后应尽量减少对牙本质的切削,将根管壁棱角处修整圆滑以减少应力集中,从而减少牙根折裂的风险。.

来源:Zhonghua Kou Qiang Yi Xue Za Zhi,查看原文。版权归原作者所有。

引用

  1. Fu M, Huang XX, Wang WD, et al. [Impact of fractured file removal from the middle third root canal on vertical root fracture resistance: three-dimensional finite element analysis]. Zhonghua Kou Qiang Yi Xue Za Zhi. 2019. PMID: 30955295. doi:10.3760/cma.j.issn.1002-0098.2019.04.006

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。