文献速递牙体牙髓病

微计算机断层扫描评估弯曲根管中单支旋转与往复式滑行路径器械的偏移、居中比、根管面积及体积变化:实验室研究

Microcomputed Assessment of Transportation, Centering Ratio, Canal Area, and Volume Increase after Single-file Rotary and Reciprocating Glide Path Instrumentation in Curved Root Canals: A Laboratory Study.
PubMed 文献 · J Endod · 2019-03-30

本研究采用微计算机断层扫描(micro-CT)比较ProGlider(PG)、WaveOne Gold Glider(WOGG)和R-Pilot(RP)三种滑行路径器械在24颗下颌第一磨牙中度弯曲近中根管中的偏移、居中能力及结构模型指数(SMI)、表面积和体积变化。结果显示WOGG和RP在所有根管三分之一区域的居中能力均优于PG(P<.05),且在根中三分之一和冠三分之一区域的偏移更小(P<.05);WOGG和RP组的体积和表面积增加显著低于PG组(P<.05)。结论认为WOGG和RP对根管系统的改变相似,而PG导致显著更高的体积和表面积增加。

要点

  • WOGG和RP在根尖、根中、根冠三分之一区域的居中能力均优于PG。
  • 在根中及根冠三分之一,WOGG和RP的根管偏移小于PG。
  • WOGG和RP的根管体积和表面积增加显著低于PG。

核心结论

  • WOGG和RP两种滑行路径器械对根管系统的改变程度相似,且均显著低于PG。
  • PG导致根管体积和表面积增加显著高于WOGG和RP。

研究设计与样本

  • 实验室研究,使用24颗具有两个独立近中根管且中度(10°-20°)弯曲的下颌第一磨牙。
  • 预备前进行micro-CT扫描,将牙齿分为PG、WOGG和RP三组,每组n=10,然后行滑行路径预备。
  • 预备后通过micro-CT分析根管体积、表面积、SMI、偏移及根尖、根中、根冠三分之一的居中能力变化。
  • 统计采用单因素方差分析和Kruskal-Wallis检验,显著性水平设为5%(P<.05)。

主要发现

  • WOGG和RP在所有三分之一区域的居中能力均优于PG(P<.05)。
  • 根尖三分之一各组根管偏移程度无显著差异(P>.05)。
  • 根中三分之一和根冠三分之一,WOGG和RP组的偏移小于PG组(P<.05)。
  • SMI变化各组间无显著差异(P>.05)。
  • WOGG和RP组的根管体积和表面积变化显著低于PG组(P<.05)。

临床怎么用

  • 在弯曲根管滑行路径预备中,优先选择WOGG或RP可能减少根管偏移和体积增加。
  • PG可能带来更大的根管体积和表面积增加,需权衡使用。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: The aim of this study was to compare the transportation and centering abilities of the ProGlider (PG; Dentsply-Sirona, Ballaigues, Switzerland), WaveOne Gold Glider (WOGG; Dentsply-Sirona), and R-Pilot (RP; VDW, Munich, Germany) file systems and the changes in the structure model index (SMI), surface area, and root canal volume (after creating the glide path in the mandibular first molar teeth's mesial canals with moderate curvature) using the micro-computed tomographic (micro-CT) method. METHODS: In the present study, 24 mandibular first molar teeth with 2 separate mesial canals and moderate (10°-20°) curvature were used. After scanning with micro-CT imaging before the procedure, the teeth were divided into 3 groups, PG, WOGG, and RP (n = 10/each group), followed by the glide path procedure. After the root canal preparation, changes in the root canals regarding the volume, surface area, SMI, transportation made by the files, and the change of their centering ability in the apical, middle, and coronal third were analyzed by micro-CT imaging. The data were statistically evaluated using 1-way analysis of variance and the Kruskal-Wallis test with a significance level set at 5% (P < .05). RESULTS: The WOGG and RP file systems showed better centering abilities at all thirds compared with the PG file system (P < .05). No significant difference was found in the apical third between the groups in terms of canal transportation degree (P > .05). However, in the WOGG and RP groups, less transportation was observed in the middle and coronal thirds compared with the PG group (P < .05). When the SMI changed, after the root canal preparation was compared, no significant differences were found between the groups (P > .05). Nevertheless, the changes in volume and surface area of the root canal in the WOGG and RP groups were significantly lower than in the PG group (P < .05). CONCLUSIONS: The WOGG and RP file systems caused similar levels of change in the root canal systems based on all parameters. Moreover, it was determined that the PG file system caused a significantly higher volume and surface area increase than the WOGG and RP file systems.

来源:J Endod,查看原文。版权归原作者所有。

引用

  1. Aydın ZU, Keskin NB, Özyürek T, et al. Microcomputed Assessment of Transportation, Centering Ratio, Canal Area, and Volume Increase after Single-file Rotary and Reciprocating Glide Path Instrumentation in Curved Root Canals: A Laboratory Study. J Endod. 2019. PMID: 30935620. doi:10.1016/j.joen.2019.02.012

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。