文献速递牙体牙髓病

MTA基封闭剂及添加铝酸钙与银颗粒对骨组织反应的影响

Bone tissue response to an MTA-based endodontic sealer, and the effect of the addition of calcium aluminate and silver particles.
PubMed 文献 · Int Endod J · 2019-05-15

研究在大鼠股骨手术腔中评估MTA基根管封闭剂MTA Fillapex及其添加不同浓度C3A或C3A+Ag后的骨组织反应,并设AH Plus、EndoSequence BC及空白对照。结果显示炎症反应从30天到90天显著降低,90天时改性封闭剂组仍可见纤维,而部分商用材料与对照组已完全形成硬组织屏障。

要点

  • MTA Fillapex添加C3A或C3A+Ag后骨修复潜力未优于商用生物陶瓷材料。
  • 大鼠骨组织炎症反应从30天至90天显著下降。
  • 90天时改性封闭剂组仅见部分矿化组织沉积。

核心结论

  • MTA Fillapex添加C3A和C3A+Ag可部分改善骨组织修复的假设仅被部分接受,改性材料未达到商用生物陶瓷材料的修复潜力。

研究设计与样本

  • 在大鼠股骨制备手术腔并植入封闭剂,于7、30、90天进行组织学观察,比较MTA Fillapex、添加C3A或C3A+Ag的MTA Fillapex、AH Plus、EndoSequence BC及空白对照的骨组织反应。

主要发现

  • 炎症反应从30天到90天显著降低(P < 0.05)。
  • 7天和30天各组纤维凝聚情况相似(P > 0.05)。
  • 90天时EndoSequence BC、AH Plus、MTA Fillapex和对照组多数标本纤维消失,而改性封闭剂组仍可见纤维(P < 0.05)。
  • 90天时AH Plus、EndoSequence BC和对照组全部标本完全形成硬组织屏障,MTA Fillapex组及改性封闭剂组仅见部分矿化组织沉积。

临床怎么用

  • 提示MTA Fillapex添加C3A或C3A+Ag后骨组织修复表现未优于商用生物陶瓷封闭剂,临床选择封闭剂时应关注材料骨组织相容性与修复潜力。

局限性

  • 原文未明确报告样本量分配、具体浓度梯度及统计效能等细节,结论外推需谨慎。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIM: To evaluate bone tissue reactions in rats to an MTA-based endodontic sealer with and without the addition of various concentrations of C3A or C3A + Ag. METHODOLOGY: Bone tissue reactions were evaluated in 45 Wistar rats after 7, 30 and 90 days (n = 5 per period). Three surgical cavities were prepared on the right femur and filled with 0.2 mL MTA Fillapex, MTA Fillapex + C3A and C3A + Ag at various concentrations: AH Plus (Dentsply DeTrey GmbH, Konstanz, Germany), EndoSequence BC (Brasseler USA, Savannah, GA, USA) or no sealer (negative control). By the end of each experimental period, animals were randomly euthanized. The samples were histologically processed and analysed using a light microscope. The presence of inflammatory cells, fibres and hard tissue barrier formation was evaluated. Data were analysed statistically using nonparametric tests to compare the differences between groups. Multiple groups were compared using the Kruskal-Wallis and Mann-Whitney U-tests with a Bonferroni correction at P = 0.05. RESULTS: The inflammatory response significantly decreased from 30 to 90 days (P < 0.05). Fibre condensation was similar amongst the groups at 07 and 30 days after intervention (P > 0.05). At 90 days, however, fibres were absent in most specimens of EndoSequence BC Sealer, AH Plus, MTA Fillapex and the control group, whilst they were still observed in samples of the modified sealers (P < 0.05). At 90 days, all specimens of AH Plus, EndoSequence BC Sealer and control group had complete formation of hard tissue barrier. In the MTA Fillapex group, as well as in the modified sealers groups, partial deposition of mineralized tissue was noticed. CONCLUSION: The hypothesis tested that the incorporation of C3A and C3A + Ag particles to MTA Fillapex would improve bone tissue repair was partially accepted, since modified MTA Fillapex did not have the same repair potential as the commercial bioceramic material.

来源:Int Endod J,查看原文。版权归原作者所有。

引用

  1. Almeida LH, Gomes APN, Gastmann AH, et al. Bone tissue response to an MTA-based endodontic sealer, and the effect of the addition of calcium aluminate and silver particles. Int Endod J. 2019. PMID: 31034099. doi:10.1111/iej.13135

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。