文献速递牙体牙髓病

GentleWave系统在离体人磨牙再治疗中去除牙胶与封闭剂的效果

Effectiveness of Gutta-percha/Sealer Removal during Retreatment of Extracted Human Molars Using the GentleWave System.
PubMed 文献 · J Endod · 2019-03-30

结果显示GentleWave去除残留材料平均26%,侧方开口针16%,EndoVac 9%,但GentleWave与两者差异无统计学意义(P > .05),侧方开口针与EndoVac差异有统计学意义(P = .04)。

要点

  • GentleWave平均去除26%残留充填材料,侧方开口针16%,EndoVac 9%。
  • GentleWave与侧方开口针、EndoVac差异无统计学意义(P > .05)。
  • 侧方开口针与EndoVac差异有统计学意义(P = .04)。

核心结论

  • 三种冲洗技术均无法完全去除根管内残留充填材料。
  • GentleWave和侧方开口针平均去除残留材料多于EndoVac,但差异无统计学意义。

研究设计与样本

  • 再治疗使用冠向下法预备至20.04,拍摄X线片和微计算机断层扫描确认残留材料,随机分为侧方开口针、EndoVac和GentleWave三组,冲洗后再次扫描计算去除百分比。

主要发现

  • GentleWave组平均去除残留充填材料26%,侧方开口针组16%,EndoVac组9%。
  • GentleWave与侧方开口针、EndoVac两组差异均无统计学意义(P > .05)。
  • 侧方开口针与EndoVac差异有统计学意义(P = .04)。

关键数值与推荐

  • 去除残留充填材料百分比:GentleWave 26%,侧方开口针16%,EndoVac 9%。
  • GentleWave vs 侧方开口针 vs EndoVac:P > .05;侧方开口针 vs EndoVac:P = .04。

临床怎么用

  • 再治疗中可考虑使用GentleWave或侧方开口针冲洗,两者去除残留充填材料效果相近。
  • EndoVac去除残留充填材料效果可能较差,但需结合临床情况选择。

局限性

  • 研究为离体牙实验,结果不能直接推广至临床。
  • 仅评估了下颌磨牙,其他牙位结果可能不同。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: The goal of endodontic retreatment is to address the etiology responsible for failure. In order to achieve this, the contents of the previous treatment must be removed. The aim of this study was to compare the effectiveness of the removal of residual obturation material (gutta-percha and sealer) using side-vented needle, EndoVac, and GentleWave (Sonendo, Inc, Laguna Hills, CA) irrigation protocols. METHODS: Thirty freshly extracted mandibular molars were instrumented to a master apical file size of 20.06, obturated using continuous wave of condensation and AH Plus sealer (Dentsply Tulsa, Tulsa, OK), restored, and placed in phosphate-buffered saline for 7 days. Teeth were retreated using a crown-down method to a master apical file size of 20.04. Radiographs and micro-computed tomographic images were obtained to confirm the presence of residual obturation material. Teeth were randomly divided among the following treatment groups: a side-vented needle, EndoVac, or GentleWave. Following strict irrigation protocols, postirrigation micro-computed tomographic scans were obtained and used to calculate the percentage of the residual obturation removed. RESULTS: GentleWave removed more residual obturation material (26%) than the side-vented needle (16%) and EndoVac (9%); the differences between the GentleWave group and the other 2 groups were not statistically significant (P > .05). The difference between the side-vented needle and EndoVac was statistically significant (P = .04). CONCLUSIONS: None of the irrigation techniques were able to completely remove all of the residual obturation material from the canals. The side-vented needle and the GentleWave groups were able to remove on average more residual obturation material than EndoVac; however, the differences were not significant.

来源:J Endod,查看原文。版权归原作者所有。

引用

  1. Wright CR, Glickman GN, Jalali P, et al. Effectiveness of Gutta-percha/Sealer Removal during Retreatment of Extracted Human Molars Using the GentleWave System. J Endod. 2019. PMID: 30935619. doi:10.1016/j.joen.2019.02.009

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。