两种水化硅酸钙根管封闭剂再治疗可去除性的微CT分析
本研究用离体下颌单根前磨牙比较BioRoot RCS与GuttaFlow Bioseal两种硅酸钙基封闭剂在旋转器械结合辅助冲洗 agitation 下的再治疗可去除性。微CT显示GuttaFlow Bioseal残留体积显著小于BioRoot RCS;辅助冲洗仅对BioRoot RCS的去除有改善。
要点
- GuttaFlow Bioseal根充物残留体积显著小于BioRoot RCS。
- 辅助冲洗 agitation 仅减少BioRoot RCS残留,对GuttaFlow Bioseal无显著影响。
- Tornado Brush与超声活化冲洗在BioRoot RCS去除中效果相当。
核心结论
- 旋转器械加冲洗去除后,GuttaFlow Bioseal的根充物残留体积显著小于BioRoot RCS。
- 辅助冲洗 agitation 可减少BioRoot RCS的残留体积,但对GuttaFlow Bioseal无显著作用。
研究设计与样本
- 样本在磷酸盐缓冲盐水中储存4个月后,用旋转器械去除根充物,再随机分入注射器冲洗、Tornado Brush或超声活化冲洗亚组(n=12)。
- 用微CT扫描计算残留根充物体积,采用双因素方差分析和Tukey事后检验(P=0.05)。
主要发现
- GuttaFlow Bioseal组根充物残留体积显著小于BioRoot RCS组(P<0.05)。
- GuttaFlow Bioseal组内各辅助冲洗亚组间残留体积无显著差异(P>0.05)。
- BioRoot RCS组中Tornado Brush和超声活化冲洗亚组的残留体积显著小于注射器冲洗亚组(P<0.05),两者间无显著差异(P>0.05)。
临床怎么用
- 再治疗去除BioRoot RCS时,可考虑联合使用Tornado Brush或超声活化冲洗以减少残留。
- 去除GuttaFlow Bioseal时,辅助冲洗 agitation 未见额外获益。
局限性
- 本研究为离体牙实验室微CT分析,结果需临床验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIM: To investigate the retreatability of two calcium silicate-based materials (BioRoot RCS, Septodont, Saint-Maur-des-Fossés, France and GuttaFlow Bioseal, Colténe/Whaledent AG, Langenau, Germany) using rotary instrumentation combined with supplementary irrigant agitation techniques using extracted teeth in a laboratory setting. METHODOLOGY: The root canals of extracted single-rooted mandibular premolars were prepared to size 40, .04 taper and randomly divided into two experimental groups (n = 36) depending on the root filling material. Root canals were filled with gutta-percha and GuttaFlow Bioseal (GB, group 1) or BioRoot RCS (BR, group 2), scanned using a micro-CT scanner and stored in phosphate-buffered saline for 4 months. Removal of root filling was performed with rotary instruments, and specimens were randomly allocated to one of the subgroups for supplementary irrigant agitation (n = 12): subgroup A, syringe irrigation (control); subgroup B, Tornado Brush (M.I.B, Suresnes, France) and subgroup C, ultrasonically activated irrigation. Specimens were re-scanned with micro-CT to calculate the volume of remnant root filling material. Data were analysed statistically by two-way ANOVA and post hoc Tukey's tests (P = 0.05). RESULTS: Specimens filled with GuttaFlow Bioseal were associated with a significantly smaller volume of root filling remnants compared with BioRoot RCS (P < 0.05). There was no significant difference between the supplementary irrigant agitation subgroups in the removal of GB (P > 0.05). In group 2 (BioRoot RCS), subgroups B (Tornado Brush) and C (ultrasonically activated irrigation) were associated with a significantly smaller volume of root filling remnants compared with subgroup A (syringe irrigation) (P < 0.05). There was no significant difference between subgroups B and C (P > 0.05). CONCLUSIONS: Significantly smaller volumes of root filling remnants of GuttaFlow Bioseal, than BioRoot RCS, were present after their removal with rotary instruments and irrigation. Supplementary irrigant agitation techniques were associated with smaller volumes of remnants during the removal of BioRoot RCS but not that of GuttaFlow Bioseal.
引用
- Pedullà E, Abiad RS, Conte G, et al. Retreatability of two hydraulic calcium silicate-based root canal sealers using rotary instrumentation with supplementary irrigant agitation protocols: a laboratory-based micro-computed tomographic analysis. Int Endod J. 2019. PMID: 31025364. doi:10.1111/iej.13132
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。