自适应与连续旋转运动下镍钛锉扭矩生成的体外比较

Comparison of In Vitro Torque Generation during Instrumentation with Adaptive Versus Continuous Movement.
PubMed 文献 · J Endod · 2019-03-29

本体外研究比较连续与自适应运动下两种镍钛旋转系统在S形树脂根管中产生的扭矩。结果显示K3XF自适应运动组总扭矩和最大扭矩显著低于连续旋转组;Twisted File自适应锉扭矩更低且预备时间更短。提示自适应运动可降低扭矩而不增加预备时间。

要点

  • 自适应运动可降低镍钛锉总扭矩和最大扭矩。
  • Twisted File自适应锉扭矩低于K3XF且预备时间更短。
  • 较小横截面积锉配合自适应运动或减少牙本质损伤风险。

核心结论

  • 在本研究条件下,镍钛锉采用自适应运动可降低扭矩生成而不增加预备时间。
  • 较小横截面积的镍钛锉配合自适应运动可能有助于降低根牙本质损伤的潜在风险。

研究设计与样本

  • 分组为K3XF连续旋转、K3XF自适应运动、Twisted File自适应运动。
  • 预备至相同尺寸后,用.06/25锉(K3XF或SM2)进行最终预备并记录扭矩和预备时间。
  • 数据分析采用单因素方差分析和Tukey事后比较检验,显著性水平95%。

主要发现

  • K3XF自适应运动组的总扭矩和最大扭矩值显著低于K3XF连续旋转组。
  • Twisted File自适应运动组的扭矩生成显著低于K3XF自适应和连续旋转组,且预备时间更短(P < .05)。

临床怎么用

  • 临床可考虑对镍钛锉采用自适应运动模式以降低扭矩,可能减少根牙本质损伤风险。
  • 选择较小横截面积的镍钛锉配合自适应运动可能有助于进一步降低扭矩。

局限性

  • 研究为体外模拟树脂块实验,结果不能直接等同于临床真实根管条件。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: The purpose of this in vitro study was to compare the torque generated by continuous and adaptive movements of 2 nickel-titanium rotary file systems. METHODS: Forty-five simulated resin blocks with an S-shaped canal were randomly divided into 3 groups (n = 15) according to the file system and kinematics: the K3XF rotary system (Kerr Endodontics, Orange, CA) with continuous rotary movement, the K3XF with adaptive movement, and the Twisted File (Kerr Endodontics) adaptive file with adaptive movement. After creating a glide path, the canal was instrumented to the same size (.04/#20 for K3XF or SM1 for the Twisted File with adaptive movement) before torque measurement. During the final instrumentation procedure with the .06/25 sized file (K3XF or SM2), the generated torque and the preparation time were recorded. The total torque experienced and the maximum torque value were calculated. The data were statistically analyzed using 1-way analysis of variance and the Tukey post hoc comparison test at a significance level of 95%. RESULTS: The K3XF file system used with adaptive motion group showed significantly lower total and maximum torque values compared with the K3XF with continuous rotary movement group. The Twisted File adaptive file with adaptive motion showed significantly lower torque generation and shorter preparation time than the K3XF groups with adaptive or continuous rotation (P < .05). CONCLUSIONS: Under the conditions of this study, adaptive movement for nickel-titanium files may reduce torque generation without increasing preparation time. Nickel-titanium files with a smaller cross-sectional area using adaptive movement may be helpful to reduce the potential risk of root dentin damage.

来源:J Endod,查看原文。版权归原作者所有。

引用

  1. Kwak SW, Ha JH, Cheung GS, et al. Comparison of In Vitro Torque Generation during Instrumentation with Adaptive Versus Continuous Movement. J Endod. 2019. PMID: 30935617. doi:10.1016/j.joen.2019.02.010

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。