文献速递牙体牙髓病

三维打印牙髓外科手术导板的准确性:一项人类尸体研究

Accuracy of 3-dimensional-printed Endodontic Surgical Guide: A Human Cadaver Study.
PubMed 文献 · J Endod · 2019-03-29

本研究在尸体模型上采用裂口设计,比较基于锥形束CT(CBCT)设计的三维打印手术导板与徒手CBCT估算方法在牙髓外科手术中的准确性,共纳入48个牙根。结果显示导板组手术入点平均偏差1.743 mm,显著小于徒手组的2.638 mm(P < .001),且导板组24个样本均获临床成功,徒手组仅11/24成功。

要点

  • CBCT设计的三维打印导板可提高牙髓外科手术入路的准确性。
  • 导板组平均偏差1.743 mm,显著低于徒手组的2.638 mm。
  • 导板组临床成功率为24/24,徒手组仅为11/24。

核心结论

  • 使用CBCT设计的三维打印手术导板较徒手CBCT估算方法能更准确进入牙根根尖区。

研究设计与样本

  • 采用裂口设计的尸体模型研究,共纳入48个牙根。
  • 实验组使用Blue Sky Bio软件设计导板,Form 2三维打印机打印,导板设计为距根尖3 mm处进入并控制深度至根舌/腭侧表面。
  • 对照组仅根据CBCT扫描视觉估算进行徒手手术入路。
  • 计划与术后CBCT图像叠加,使用Invivo软件测量手术入点与计划目标的偏差。
  • 采用双尾t检验和Fisher精确检验比较两组偏差。

主要发现

  • 导板组平均偏差为1.743 mm,徒手组为2.638 mm,差异有统计学意义(P < .001)。
  • 导板组24个样本均被判定为临床成功(位于根尖区),徒手组仅11/24成功。

临床怎么用

  • 在牙髓外科手术中,可考虑使用CBCT设计的三维打印导板以提高根尖入路的准确性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: Cone-beam computed tomographic (CBCT)-based 3-dimensional-printed surgical guides, such as those used in implant placement and orofacial surgery, allow for accurate planning and performance of surgical procedures. The objective of this study was to evaluate the accuracy of CBCT-designed surgical guides for use during endodontic surgery. METHODS: A split-mouth design was conducted using 48 roots in a cadaver model. In the experimental group, using information from the preoperative CBCT scans and digital impressions, surgical guides were designed using Blue Sky Bio (Grayslake, IL) planning software and printed using a Form 2 3-dimensional printer (Formlabs, Somerville, MA). The guides were designed to allow for surgical access at 3 mm from the apex of each root with depth control to the lingual or palatal surface of the root. In the control group, surgical access was completed "freehand" by visually approximating measurements from the CBCT scan only. The planned and postoperative CBCT images were superimposed, and the deviation of the surgical access point from the planned target was measured using Invivo software (Anatomage, San Jose, CA). A 2-tailed t test and the Fisher exact test were conducted to compare the deviation in the experimental CBCT-guided group versus the control CBCT-approximated freehand group. RESULTS: The mean deviation for the guided group (1.743 mm) was significantly less than that of the approximated freehand group (2.638 mm, P < .001). Only in 11 of the 24 samples of the control group was surgical access considered clinically successful (within the apical area of the root), whereas all 24 of the experimental samples were considered clinically successful. CONCLUSIONS: Using a CBCT-designed printed surgical guide is a more accurate method for access to the apical portion of the root during surgical endodontics compared with a "freehand" CBCT-approximated method.

来源:J Endod,查看原文。版权归原作者所有。

引用

  1. Ackerman S, Aguilera FC, Buie JM, et al. Accuracy of 3-dimensional-printed Endodontic Surgical Guide: A Human Cadaver Study. J Endod. 2019. PMID: 30930013. doi:10.1016/j.joen.2019.02.005

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。