Resilon充填材料在未愈合病例中的降解评估
本研究纳入既往用Resilon或牙胶尖充填后根管未愈合需再治疗的患者,开髓后评估原充填材料是否降解。双变量分析显示Resilon降解比例显著高于牙胶尖(P = .0003),提示Resilon在未愈合病例中更易降解。
要点
- 开髓后若根管内缺乏坚实致密材料、15号K锉可被动到达工作长度,则判定为充填材料降解。
- 在未愈合需再治疗的病例中,Resilon降解比例显著高于牙胶尖(P = .0003)。
- Resilon降解可能影响根管再治疗时的材料清除与临床预后。
核心结论
- 临床观察性研究提示,在未愈合病例中Resilon的降解率高于牙胶尖。
研究设计与样本
- 纳入既往用Resilon或牙胶尖充填、根管未愈合需再治疗的患者,开髓后评估原充填材料为降解或完整。
主要发现
- 双变量分析显示两种材料的降解比例差异有统计学意义,Resilon降解可能性高于牙胶尖(P = .0003)。
关键数值与推荐
- 开髓后根管内缺乏坚实致密材料,且15号K锉可被动到达工作长度,即判定充填材料为降解。
临床怎么用
- 对既往Resilon充填的未愈合病例再治疗时,应评估充填材料是否降解并彻底清理根管。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: The Resilon obturation system (Pentron Clinical Technologies, Wallingford, CT) was discontinued a few years after its introduction as an alternative to traditional gutta-percha and sealer. Ex vivo models support anecdotal reports of degraded Resilon filling material; however, there is no previous clinical report of this degradation. This may represent a significant health concern for the patient and contribute to a higher clinical failure rate of Resilon-obturated root canals. The aim of this study was to determine the proportion of Resilon degradation in nonhealed endodontic cases compared with gutta-percha and sealer. METHODS: Patients previously treated with Resilon or gutta-percha who had a nonhealed root canal that needed retreatment were enrolled. Upon access, the previous filling material was classified as either degraded or intact. If there was a lack of solid, dense material remaining within the canal confirmed by passively placing a size 15 K-file to the working length, the filling material was considered to be degraded. RESULTS: The proportion of degradation between the 2 materials was statistically significant, with Resilon having a higher likelihood of degradation than gutta-percha in the bivariate analysis (P = .0003). CONCLUSIONS: This clinical observational study indicates that Resilon has a higher rate of degradation when compared with gutta-percha in nonhealed cases.
引用
- Payne LA, Tawil PZ, Phillips C, et al. Resilon: Assessment of Degraded Filling Material in Nonhealed Cases. J Endod. 2019. PMID: 31005333. doi:10.1016/j.joen.2019.02.019
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。