文献速递牙体牙髓病

Micro-CT评价XP-Endo Finisher辅助去除根管充填物的效果

Micro-CT evaluation of the removal of root fillings using the ProTaper Universal Retreatment system supplemented by the XP-Endo Finisher file.
PubMed 文献 · Int Endod J · 2019-02-22

研究以30颗离体下颌第一磨牙近中颊根管为对象,比较PTUR系统去除充填物后加用XP-Endo Finisher的清洁效果,并用micro-CT测量剩余充填物体积。结果显示加用XP-Endo Finisher后各封闭剂组的充填物去除均显著改善,与封闭剂类型无关。

要点

  • PTUR配合F3预备后加用XP-Endo Finisher可显著减少根管内剩余充填物
  • 该附加预备的改善效果不受所用封闭剂类型影响
  • 研究为离体牙micro-CT实验,结论需临床验证

核心结论

  • 在下颌第一磨牙近中颊根管中,PTUR系统配合F3 ProTaper器械后加用XP-Endo Finisher可增强根管充填物的去除。

研究设计与样本

  • 离体牙实验,30颗拔除下颌第一磨牙的近中颊根管,ProTaper Universal镍钛锉预备至F2并以单尖法充填,每组10个根管,分别使用AH Plus、NeoMTA Plus和EndoSequence BC封闭剂。
  • 用PTUR系统去除充填物并追加根尖预备(ProTaper F2和F3),随后加用XP-Endo Finisher预备。
  • 于再治疗前、再治疗后及使用XP-Endo Finisher后行micro-CT扫描,评估剩余充填材料体积,采用Kruskal-Wallis检验和Friedman双向方差分析并作Bonferroni校正。

主要发现

  • 各组初始充填体积无显著差异(P > 0.05)。
  • 旋转器械再治疗后各组充填材料量均显著减少(P < 0.05)。
  • 初次再治疗后各组剩余充填物体积相近(P > 0.05)。
  • 加用XP-Endo Finisher后,无论封闭剂类型如何,充填材料去除均得到改善(P < 0.05)。

临床怎么用

  • 对下颌第一磨牙近中颊根管再治疗,在PTUR与F3预备后可将XP-Endo Finisher作为附加清洁步骤以提升充填物去除效果。

局限性

  • 研究为离体牙micro-CT实验,样本为30个根管,结论需临床研究验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIM: To compare the removal of root fillings in extracted teeth using the ProTaper Universal Retreatment system (PTUR) followed by a supplementary preparation with the XP-Endo Finisher file. METHODOLOGY: The mesiobuccal root canals of 30 extracted mandibular first molars were instrumented with ProTaper Universal NiTi files up to F2 and filled with one of the following sealers using a single-cone technique (n = 10): AH Plus, NeoMTA Plus and EndoSequence BC. The root fillings were removed using the PTUR system with additional apical preparation using ProTaper F2 and F3 files. Then, an additional preparation with an XP-Endo Finisher file was performed. The samples were scanned using micro-CT before and after retreatment and again after the use of the XP-Endo Finisher to assess the volume of remaining filling material. Data were analysed by Kruskal-Wallis and Friedman's two-way analysis of variance tests with Bonferroni correction. RESULTS: No significant difference in the initial filling volume was observed amongst the groups (P > 0.05). The amount of filling materials in each group decreased significantly after retreatment with rotary files (P < 0.05). After initial retreatment, the volume of the remaining filling amongst the groups was similar (P > 0.05). Additional preparation with the XP-Endo Finisher improved the removal of filling materials regardless of the sealer type (P < 0.05). CONCLUSIONS: In the mesiobuccal root canals of extracted mandibular first molars, additional preparation using an XP-Endo Finisher file, after using the PTUR system and F3 ProTaper instruments, enhanced the removal of filling materials from root canals.

来源:Int Endod J,查看原文。版权归原作者所有。

引用

  1. Aksel H, Küçükkaya Eren S, Askerbeyli Örs S, et al. Micro-CT evaluation of the removal of root fillings using the ProTaper Universal Retreatment system supplemented by the XP-Endo Finisher file. Int Endod J. 2019. PMID: 30715732. doi:10.1111/iej.13094

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。