文献速递牙体牙髓病

XP-endo Shaper、Reciproc Blue与ProTaper Universal镍钛系统对牙本质微裂纹形成的微计算机断层扫描评估

Evaluation of XP-endo Shaper, Reciproc Blue, and ProTaper Universal NiTi Systems on Dentinal Microcrack Formation Using Micro-Computed Tomography.
PubMed 文献 · J Endod · 2019-01-01

本研究采用微计算机断层扫描(μCT)分析比较XP-endo Shaper(XP)、Reciproc Blue(RB)和ProTaper Universal(PTU)三种镍钛器械根管预备后牙本质微裂纹的发生频率。

要点

  • XP和RB器械根管预备后未诱导新牙本质微裂纹形成。
  • PTU系统显著增加牙本质微裂纹百分比(P < .05)。
  • 微裂纹评估采用μCT扫描预备前后横截面图像。

核心结论

  • XP和RB系统根管预备可能不会在近中根诱导新牙本质微裂纹形成。
  • PTU系统显著增加了微裂纹百分比,建议进一步评估这些器械使用后微裂纹形态。

研究设计与样本

  • 采用微计算机断层扫描(μCT)分析离体牙根管预备前后牙本质微裂纹。

主要发现

  • XP和RB组未观察到新牙本质微裂纹。
  • PTU系统与术前标本相比显著增加了微裂纹百分比(P < .05)。

关键数值与推荐

  • 每组微裂纹数量以百分比表示。
  • 采用McNemar检验比较器械使用前后差异,显著性水平设定为P ≤ .05。

临床怎么用

  • 在近中根根管预备中,XP和RB系统可能减少新牙本质微裂纹的形成。
  • 使用PTU系统时需注意其可能增加牙本质微裂纹的风险。

局限性

  • 建议进一步评估这些器械使用后微裂纹的形态。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: The purpose of the present study was to evaluate the frequency of dentinal microcracks observed after root canal preparation with XP-endo Shaper (XP), Reciproc Blue (RB), and ProTaper Universal (PTU) instruments using micro-computed tomographic (μCT) analysis. METHODS: Thirty extracted mandibular first and second molars with mesial roots having 2 separate canals with an angle between 10°and 20° were randomly assigned to 3 experimental groups (n = 10) according to the different nickel-titanium systems used for root canal preparation: XP, RB, and PTU. The specimens were scanned using μCT imaging before and after root canal preparation. Then, preoperative and postoperative cross-sectional images of the teeth were evaluated to identify the presence of dentinal defects. For each group, the number of microcracks was determined as a percentage rate. The McNemar test was used to determine significant differences before and after instrumentation. The level of significance was set at P ≤ .05. RESULTS: No new dentinal microcracks were observed in the XP and RB groups. The PTU system significantly increased the percentage rate of microcracks compared with preoperative specimens (P < .05). CONCLUSIONS: Root canal preparations with XP and RB systems might not induce the formation of new dentinal microcracks on the mesial roots of mandibular molars. Further assessments are suggested for the examination of the morphology of microcracks after the use of these instruments.

来源:J Endod,查看原文。版权归原作者所有。

引用

  1. Aksoy Ç, Keriş EY, Yaman SD, et al. Evaluation of XP-endo Shaper, Reciproc Blue, and ProTaper Universal NiTi Systems on Dentinal Microcrack Formation Using Micro-Computed Tomography. J Endod. 2019. PMID: 30803543. doi:10.1016/j.joen.2018.12.005