上颌后牙区四枚或六枚种植体支持覆盖义齿的5年随机对照试验结果
本随机对照试验比较上颌后牙区植入四枚或六枚杆连接种植体支持覆盖义齿的5年临床与患者报告结局。四枚种植体组种植体存留率100%,六枚组99.5%,两组临床参数与患者满意度无显著差异,四枚种植体方案不劣于六枚。
要点
- 上颌后牙区四枚种植体支持杆连接覆盖义齿5年存留率达100%。
- 两组种植体边缘骨吸收与患者满意度无显著差异。
- 四枚种植体方案在5年随访中不劣于六枚种植体方案。
核心结论
- 经双侧上颌窦底提升后,上颌后牙区四枚种植体支持的杆连接覆盖义齿在5年评价期内不劣于六枚种植体支持的覆盖义齿。
研究设计与样本
- 所有患者先行双侧上颌窦底提升取自体髂前上棘骨,种植体骨结合3个月后制作杆支持覆盖义齿。
- 60例患者完成5年随访。
主要发现
- 四枚种植体组种植体存留率100%,六枚种植体组99.5%。
- 四枚种植体组无需重新制作覆盖义齿,六枚种植体组因义齿基托和人工牙过度磨损重新制作3例,覆盖义齿存留率90.9%。
- 两组临床参数无显著差异。
- 与基线相比,平均边缘骨丧失四枚种植体组为0.58 ± 0.51 mm,六枚种植体组为0.60 ± 0.58 mm。
- 总体患者满意度显著改善,但组间无差异。
临床怎么用
- 对于功能性上颌义齿投诉且后牙区明显吸收的无牙颌患者,经双侧上颌窦底提升后可考虑上颌后牙区四枚种植体支持杆连接覆盖义齿。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To compare clinical and patient-reported outcomes when providing maxillary overdentures on four bar- and six bar-connected implants placed in the posterior region during a 5-year follow-up period. MATERIALS AND METHODS: Sixty-six fully edentulous patients with functional maxillary denture complaints and insufficient bone volume to allow implant placement were scheduled for a maxillary sinus floor elevation procedure with bone from the anterior iliac crest and randomized to receive either four or six implants in the posterior maxilla and four implants in the mandible. After 3 months of osseointegration, a bar-supported overdenture was constructed. Maxillary implant survival, overdenture survival, clinical scores, peri-implant bone height changes and patient satisfaction were assessed. RESULTS: Sixty patients completed the 5-year follow-up. Implant survival was 100% in the four-implant group and 99.5% in the six-implant group. No new overdentures had to be made in the four-implant group, and three new overdentures were made in the six-implant group due to excessive wear of the denture base and teeth (90.9% overdenture survival). Clinical parameters did not differ significantly between groups. Mean marginal bone loss compared to baseline was 0.58 ± 0.51 mm in the four-implant group and 0.60 ± 0.58 mm in the six-implant group, respectively. Overall, patient satisfaction improved significantly, but did not differ between groups. CONCLUSION: Following a bilateral maxillary sinus floor elevation procedure, a bar-supported overdenture on four implants in the posterior maxillary region is not inferior to an overdenture supported by six implants after a 5-year evaluation period in patients with functional maxillary denture complaints and marked posterior resorption (Clinical trial registration number: NTR2969).
引用
- Slot W, Raghoebar GM, Cune MS, et al. Four or six implants in the maxillary posterior region to support an overdenture: 5-year results from a randomized controlled trial. Clin Oral Implants Res. 2019. PMID: 30636064. doi:10.1111/clr.13403
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。