XP-endo Finisher R器械优化椭圆形根管根充残留物清除
结果显示XP-endo Finisher R平均清除约32%材料,显著多于PUI的12%(P=0.015),但两种方法均无法使根管完全清洁。
要点
- XP-endo Finisher R清除椭圆形根管根充残留物效果显著优于PUI。
- XP-endo Finisher R平均清除约32%残留材料,PUI仅约12%。
- 两种辅助方法均无法完全清除椭圆形根管内的根充残留物。
核心结论
- 两种辅助方法均显著减少椭圆形根管根充残留物体积,XP-endo Finisher R清除量显著多于PUI,但均无法完全清洁根管。
主要发现
- 基线时两组根充材料体积相似(t检验,P=0.787)。
- XP-endo Finisher R清除的根充材料显著多于PUI(t检验,P=0.015),平均清除约32%对12%。
- 两种方法在各根管三分之一段内清除量无差异(XP-endo Finisher R单因素方差分析P=0.07,PUI P=0.886)。
关键数值与推荐
- XP-endo Finisher R平均清除约32%根充材料,PUI平均清除12%。
- 统计显著性水平为5%。
临床怎么用
- 再治疗椭圆形根管时,可优先选用XP-endo Finisher R辅助清除根充残留物,但需知晓其无法实现完全清洁。
局限性
- 样本量较小(每组n=10),仅为体外研究,结果需临床验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIM: To evaluate the performance of XP-endo Finisher R instruments when removing root filling remnants from oval-shaped canals using microcomputed tomographic (micro-CT) imaging as the analytical tool. Passive ultrasonic irrigation (PUI) was used as a reference technique for comparison. METHODOLOGY: Twenty mandibular incisors with oval-shaped canals were matched based on similar anatomic features of the canal (volume, aspect ratio and 3D configuration) after scanning procedures. The canals were prepared with Reciproc R25 instruments, filled with gutta-percha and AH Plus sealer using the single-cone technique and retreated up to a Reciproc R40 instrument. After retreatment procedures, the specimens were rescanned, and the homogeneity between the specimens, the oval-shaped anatomy and the remaining filling material were confirmed. The pair-matched samples were assigned to two experimental groups (n = 10), according to the supplementary approach used: XP-endo Finisher R or PUI. Each sample was scanned after each endodontic procedure. The volume of remaining root filling material was quantified before and after the use of each supplementary approach. This analysis was performed considering the total canal (Student t-test) and also by thirds (anova procedure followed by a Bonferroni correction). Data were analysed statistically with a significance level of 5%. RESULTS: The volume of root filling material at baseline was similar between the groups (t-test, P = 0.787). XP-endo Finisher R removed significantly more root filling material compared to PUI (t-test, P = 0.015), as it removed a mean of ≅32% material compared to 12% for the PUI. There was no difference in the amount of root filling material removed in the root canal thirds after using both supplementary approaches (one-way anova, P = 0.07 for XP-endo Finisher R and P = 0.886 for PUI). CONCLUSIONS: Both supplementary approaches significantly reduced the volume of remaining root filling material from oval-shaped canals. The XP-endo Finisher R instrument removed significantly more root filling material than PUI. None of the supplementary approaches was able to render oval-shaped canals completely free from remaining root filling material.
引用
- De-Deus G, Belladonna FG, Zuolo AS, et al. XP-endo Finisher R instrument optimizes the removal of root filling remnants in oval-shaped canals. Int Endod J. 2019. PMID: 30663790. doi:10.1111/iej.13077
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。