钛与二氧化锆种植体周骨缺损的根尖片与CBCT体外评估
本体外研究将18个含钛或二氧化锆种植体的模型分为无缺损、1mm宽缺损和1.5mm宽缺损三组,用根尖片和锥形束CT测量缺损宽度。根尖片测量比CBCT更准确,CBCT总是高估缺损宽度,对二氧化锆种植体高估达临床相关程度。
要点
- 根尖片测量种植体周骨缺损宽度比CBCT更准确。
- CBCT测量总是高估缺损宽度,二氧化锆种植体高估更明显。
- 钛种植体的测量准确性总体优于二氧化锆种植体。
核心结论
- 根尖片评估钛和二氧化锆种植体邻面种植体周缺损宽度比CBCT更准确。
- CBCT测量总是高估缺损宽度,对二氧化锆种植体达到临床相关程度。
研究设计与样本
- 体外研究,共18个牙石模型,每个含一个钛和一个二氧化锆种植体。
- 模型分三组:A无缺损、B 1mm宽缺损、C 1.5mm宽缺损,每组6个模型。
- 缺损宽度用数显卡尺测量,随后进行根尖片和CBCT扫描,由三名检查者评估。
- 使用Wilcoxon符号秩检验和Wilcoxon秩和检验分析影像技术和种植体类型间的差异。
主要发现
- 根尖片测量偏差(mm):钛组A为0.01±0.03、B为-0.02±0.06、C为-0.00±0.04;二氧化锆组A为0.05±0.02、B为0.01±0.03、C为0.09±0.03。
- CBCT测量偏差(mm):钛组A为0.10±0.11、B为0.26±0.05、C为0.24±0.08;二氧化锆组A为1.07±0.06、B为0.64±0.37、C为0.54±0.17。
- 除钛种植体A组外,根尖片测量均显著比CBCT更准确(p≤0.05)。
- 两种方法对钛种植体的测量通常比二氧化锆种植体更准确。
临床怎么用
- 临床评估种植体周邻面骨缺损宽度时,根尖片可能比CBCT更准确。
- 使用CBCT测量缺损宽度时需注意其高估倾向,尤其对二氧化锆种植体。
局限性
- 本研究为体外模型研究,结果需临床验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To test the accuracy of measurement of interproximal peri-implant bone defects at titanium (Ti) and zirconium dioxide (ZrO2 ) implants by digital periapical radiography (PR) and cone beam computed tomography (CBCT). MATERIAL AND METHODS: A total of 18 models, each containing one Ti and one ZrO2 implant, were cast in dental stone. Six models each were allocated to following defect groups: A-no peri-implant defect, B-1 mm width defect, C-1.5 mm width defect. The defect width was measured with a digital sliding caliper. Subsequently, the models were scanned by means of PR and CBCT. Three examiners assessed the defect width on PR and CBCT. Wilcoxon signed-rank test and Wilcoxon rank sum test were applied to detect differences between imaging techniques and implant types. RESULTS: For PR, the deviation of the defect width measurement (mm) for groups A, B, and C amounted to 0.01 ± 0.03, -0.02 ± 0.06, and -0.00 ± 0.04 at Ti and 0.05 ± 0.02, 0.01 ± 0.03, and 0.09 ± 0.03 at ZrO2 implants. The corresponding values (mm) for CBCT reached 0.10 ± 0.11, 0.26 ± 0.05, and 0.24 ± 0.08 at Ti and 1.07 ± 0.06, 0.64 ± 0.37, and 0.54 ± 0.17 at ZrO2 implants. Except for Ti with defect A, measurements in PR were significantly more accurate in comparison to CBCT (p ≤ 0.05). Both methods generally yielded more accurate measurements for Ti than for ZrO2 . CONCLUSIONS: The assessment of interproximal peri-implant defect width at Ti and ZrO2 implants was more accurate in PR in comparison to CBCT. Measurements in CBCT always led to an overestimation of the defect width, reaching clinical relevance for ZrO2 implants.
引用
- Steiger-Ronay V, Krcmaric Z, Schmidlin PR, et al. Assessment of peri-implant defects at titanium and zirconium dioxide implants by means of periapical radiographs and cone beam computed tomography: An in-vitro examination. Clin Oral Implants Res. 2018. PMID: 30387207. doi:10.1111/clr.13383
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。