文献速递牙体牙髓病

三种镍钛系统联合XP-endo Finisher R对下颌磨牙根管再治疗充填物清除的影响

Effects of preparation with the Self-Adjusting File, TRUShape and XP-endo Shaper systems, and a supplementary step with XP-endo Finisher R on filling material removal during retreatment of mandibular molar canals.
PubMed 文献 · Int Endod J · 2018-12-07

三种系统清除充填物的质量百分比分别为92.4%、96.9%和96.9%,组间无显著差异;XP-endo Shaper完全清除率70%显著高于TRUShape的30%。补充使用XP-endo Finisher R可额外去除38%的充填物(P<0.001)。

要点

  • SAF、TRUShape与XP-endo Shaper在根尖5 mm清除充填物质量上效果相当。
  • XP-endo Shaper完全清除率70%高于TRUShape的30%(P=0.03)。
  • 补充XP-endo Finisher R可额外去除38%充填物(P<0.001)。

核心结论

  • 三种系统在清除下颌磨牙根尖5 mm充填物质量上效果相当,XP-endo Shaper完全清除率高于TRUShape。
  • 补充使用XP-endo Finisher R可增强充填物清除效果。

研究设计与样本

  • 先用D-RaCe系统初步去除充填物,再随机分为SAF、TRUShape和XP-endo Shaper三组(每组n=20)。
  • 用micro-CT评估根尖5 mm充填物体积,残余充填物者补充XP-endo Finisher R后再扫描。
  • 采用一般线性模型(配对数据)、Fisher精确检验和Wilcoxon符号秩检验进行统计分析。

主要发现

  • SAF、TRUShape和XP-endo Shaper清除充填物的质量百分比分别为92.4%、96.9%和96.9%,组间无显著差异(P>0.05)。
  • 完全清除充填物的根管比例:XP-endo Shaper为70%,SAF为55%,TRUShape为30%;XP-endo Shaper与TRUShape差异显著(P=0.03)。
  • 补充XP-endo Finisher R后额外去除38%的充填物(P<0.001),另有6个根管达到完全清除。

关键数值与推荐

  • 清除充填物质量百分比:SAF 92.4%,TRUShape 96.9%,XP-endo Shaper 96.9%(P>0.05)。
  • 完全清除率:XP-endo Shaper 70%,SAF 55%,TRUShape 30%;XP-endo Shaper vs TRUShape P=0.03。
  • 补充XP-endo Finisher R额外去除38%充填物(P<0.001)。

临床怎么用

  • 再治疗中可选用SAF、TRUShape或XP-endo Shaper去除根尖5 mm充填物,效果相当。
  • 对残余充填物可补充使用XP-endo Finisher R以增强清除效果。

局限性

  • 本研究为体外研究,样本为Vertucci IV型下颌磨牙近中根管,结论外推需谨慎。
  • 仅评估根尖5 mm区域,未涉及其他根管区域或临床结局。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIM: To compare the effects of three instrumentation systems, and a supplementary approach with a finishing instrument, on filling material removal during retreatment of mandibular molar canals. METHODS: Sixty mesial canals from mandibular molars (Vertucci's type IV anatomy) were instrumented, filled and subjected to retreatment. After initial removal of the root canal filling material using the D-RaCe system, the canals were randomly distributed into three groups (n = 20) according to the instrument system used for preparation: the Self-Adjusting File (SAF), TRUShape or XP-endo Shaper. The filling material volume in the apical 5 mm of the canals was assessed by means of micro-computed tomography (micro-CT) before and after retreatment. All specimens with residual filling material were subjected to a supplementary approach with the XP-endo Finisher R instrument and another micro-CT scan was taken. Data on the volumes of filling material and incidence of total removal were compared between groups by the general linear model for paired data and the Fisher's exact test. The effects of the refinement step were evaluated by the Wilcoxon Signed Ranks test. RESULTS: The amount of removed material was 92.4%, 96.9% and 96.9% for the SAF, TRUShape and XP-endo Shaper, respectively. There were no significant differences between them (P > 0.05). Canals were completely cleaned of filling material in 70% of the specimens for XP-endo Shaper, 55% for SAF and 30% for TRUShape; the difference between XP-endo Shaper and TRUShape was significant (P = 0.03). The supplementary step with the XP-endo Finisher R instrument was associated with additional filling material removal of 38% (P < 0.001). Six more canals were rendered free of filling material after using this finishing instrument. CONCLUSIONS: The tested systems were equally effective in removing the mass of filling material from the apical 5 mm of molar canals. The supplementary step with the XP-endo Finisher R instrument enhanced filling material removal.

来源:Int Endod J,查看原文。版权归原作者所有。

引用

  1. Machado AG, Guilherme BPS, Provenzano JC, et al. Effects of preparation with the Self-Adjusting File, TRUShape and XP-endo Shaper systems, and a supplementary step with XP-endo Finisher R on filling material removal during retreatment of mandibular molar canals. Int Endod J. 2018. PMID: 30417931. doi:10.1111/iej.13039

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。