根管冲洗液对根管内、峡部及牙本质小管内原位粪肠球菌生物膜的抗菌效果
结果显示6% NaOCl破坏生物膜并显著降低厚度,QMix 2 in1杀灭生物膜细菌优于SilverSol/H2O2和HYBENX。
要点
- 6% NaOCl是唯一能破坏生物膜并显著降低其厚度的冲洗液。
- 杀灭根管和峡部生物膜细菌效果:NaOCl > QMix 2 in1 > HYBENX > SilverSol/H2O2 > NaCl。
- QMix 2 in1或HYBENX因能去除玷污层无机成分,利于杀灭小管内细菌。
核心结论
- SilverSol/H2O2和HYBENX杀灭根管生物膜细菌的能力弱于QMix 2 in1。
- 与6% NaOCl相比,所有抗菌冲洗液均不能有效破坏生物膜。
研究设计与样本
- 牙根管预备、高压灭菌后接种粪肠球菌4周形成生物膜。
- 1颗标本切片行细菌特异性染色经光镜确认生物膜存在。
- 其余标本随机分为5组:0.9% NaCl、SilverSol/H2O2、HYBENX、QMix 2 in1、6% NaOCl。
- 冲洗前后取样培养48小时计数CFU,并用共聚焦激光扫描显微镜评估死菌百分比和生物膜厚度。
主要发现
- 死菌百分比显著受冲洗液因素(p < 0.001)和位置因素(p = 0.017)影响。
- 峡部和根管中死菌百分比排序均为:NaCl < SilverSol/H2O2 < HYBENX < QMix 2 in1 < NaOCl(p < 0.05)。
- 仅6% NaOCl破坏生物膜并显著降低其厚度。
- 所有消毒液均降低S2样本中粪肠球菌的CFU、代谢活性、多糖和乳酸产量。
临床怎么用
- 临床可优先使用6% NaOCl以获得破坏生物膜的效果。
- 若需杀灭牙本质小管内细菌,可考虑QMix 2 in1或HYBENX,因其能去除玷污层无机成分。
- 使用SilverSol/H2O2时,需先用其他冲洗液去除玷污层有机和无机成分,并延长作用时间以清除小管内生物膜。
局限性
- 离体研究,结果不能直接等同于临床疗效。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To investigate the anti-biofilm efficacy of root canal irrigants in canal spaces, isthmi and dentinal tubules of root canals ex vivo. METHODS: Fifty-one single-rooted premolars, each containing an isthmus, were instrumented, autoclaved and inoculated with Enterococcus faecalis for 4 weeks. One specimen was sectioned for bacteria-specific staining to confirm the presence of biofilms using light microscopiy. The remaining specimens were randomly divided to five groups: (1) 0.9% NaCl, (2) SilverSol/H2O2, (3) HYBENX, (4) QMix 2 in1, (5) 6% NaOCl. Bacterial sampling was performed before (S1) and after (S2) canal irrigation. Diluted bacteria suspension was cultured for 48 h for counting the colony forming units (CFU). Percentages of dead bacteria and biofilm thickness were evaluated by confocal laser scanning microscopy (CLSM). Metabolic activity, lactic acid and polysaccharide synthesis of E. faecalis derived from S2 samples were analysed. RESULTS: The percentages of dead bacteria were significantly affected by the factor "irrigant" (p < 0.001) and the factor "location" (p = 0.017). The percentages of dead bacteria in the isthmi and canals were both in the ordor: NaCl < SilverSol/H2O2 < HYBENX < QMix 2 in1 < NaOCl (p < 0.05). Only 6% NaOCl disrupted biofilms and significantly reduced their thickness. The CFU, metabolic activity, polysaccharide and lactic acid production of E. faecalis were all reduced by the disinfecting solutions. CONCLUSIONS: SilverSol/H2O2 and HYBENX were less adept than QMix 2 in1 at killing biofilm bacteria in root canals. None of these antibacterial irrigants were effective, compared with 6% NaOCl, in disrupting biofilms. CLINICAL SIGNIFICANCE: There is advantage in using HYBENX or QMix 2 in1 to kill intratubular bacteria biofilms because of their capability in removing the inorganic component of the smear layer. SilverSol/H2O2 requires extra time to eradicate intratubular biofilms upon removal of the organic and inorganic components of the smear layer by other root canal irrigants.
引用
- Ye WH, Fan B, Purcell W, et al. Anti-biofilm efficacy of root canal irrigants against in-situ Enterococcus faecalis biofilms in root canals, isthmuses and dentinal tubules. J Dent. 2018. PMID: 30296552. doi:10.1016/j.jdent.2018.10.002
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。