声动、超声与激光活化冲洗去除峡部模拟生物膜水凝胶的效果
本研究在含两个标准根管并经峡部相连的透明树脂模型中,比较声动、超声与激光活化冲洗清除峡部含牙本质碎屑水凝胶的效果。各组均冲洗3×20秒,激光活化冲洗去除率最高(90.2%),Eddy次之(85.9%),二者优于超声活化、EndoActivator与针头冲洗;激光活化效果不依赖器械深入根管。
要点
- 激光活化冲洗与Eddy去除峡部水凝胶效果最佳。
- 激光活化冲洗优于超声活化、EndoActivator和针头冲洗。
- Eddy优于针头冲洗和EndoActivator,与超声活化无显著差异。
核心结论
- 激光活化冲洗和Eddy去除水凝胶最多,效果优于EndoActivator和超声活化冲洗。
- 激光活化冲洗的效果不依赖工作尖深入根管内放置。
研究设计与样本
- 采用含两个标准根管的透明树脂块模型,根管尖部直径0.3 mm、锥度6%、长16 mm,带冠部储液区。
- 两根管由宽0.15 mm、高2 mm的峡部连通,峡部填充含牙本质碎屑的水凝胶。
- 模型随机分为EndoActivator、Eddy、超声活化冲洗、Er:YAG激光活化冲洗及27G针头冲洗对照共5组,每组n=20。
主要发现
- 激光活化冲洗组水凝胶去除率最高,为90.2%。
- Eddy组水凝胶去除率为85.9%。
- 激光活化冲洗显著高于超声活化、EndoActivator和针头冲洗(P ≤ 0.014),与Eddy无显著差异(P = 0.498)。
- Eddy显著高于针头冲洗和EndoActivator(P < 0.05),与超声活化无显著差异(P = 0.07)。
- 针头冲洗与EndoActivator之间无显著差异(P = 1)。
关键数值与推荐
- 所有冲洗方案执行3 × 20 s。
- 激光参数为2940 nm Er:YAG激光,20 Hz、50 μs、20 mJ,PIPS工作尖置于根管入口处。
- 超声活化使用Irrisafe 25 mm长、size 25锉。
- 组间比较采用Welch anova,显著性水平P ≤ 0.05。
临床怎么用
- 在峡部等复杂解剖区域,可优先考虑激光活化冲洗或Eddy以提升水凝胶类模拟生物膜的清除。
- 激光活化冲洗可将工作尖置于根管入口,无需深入根管内即可获得较好清除效果。
局限性
- 研究采用透明树脂块与模拟生物膜水凝胶模型,结果需在真实根管与临床生物膜中进一步验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIM: To evaluate the efficacy of sonically, ultrasonically and laser-activated irrigation (LAI) in removing a biofilm-mimicking hydrogel from the isthmus in a root canal model. METHODOLOGY: Transparent resin blocks containing two standardized root canals (apical diameter of 0.3 mm, 6% taper, 16 mm long, with a coronal reservoir) connected by an isthmus (0.15 mm wide, 2 mm high) were used as the test model. The isthmus was filled with a hydrogel-containing dentine debris. The canals were filled with irrigant, and the models were randomly assigned to the following activation groups (n = 20): EndoActivator (EA), Eddy, ultrasonically activated irrigation (UAI) with an Irrisafe 25 mm length, size 25 file and LAI with a 2940 nm Er:YAG-laser (20 Hz, 50 μs, 20 mJ, PIPS tip at the canal entrance). All protocols were executed for 3 × 20 s. Needle irrigation (NI) with a 27G needle served as the control. Standardized images of the isthmus were taken before and after irrigation, and the amount of removed hydrogel was determined using image analysis software and compared across groups using Welch anova (P ≤ 0.05). RESULTS: Hydrogel removal was greatest in the LAI group (90.2%) and was significantly greater than that with UAI, EA and NI (P ≤ 0.014), but not significantly different from Eddy (P = 0.498). Hydrogel removal with Eddy (85.9%) was significantly greater than that with NI and EA (P < 0.05), but not significantly different from UAI (P = 0.07). There was no significant difference between the NI and EA groups (P = 1). CONCLUSIONS: Laser-activated irrigation and Eddy resulted in the greatest hydrogel removal and performed better than EA and UAI. The effect of LAI was also not dependent on deep intracanal tip placement.
引用
- Swimberghe RCD, De Clercq A, De Moor RJG, et al. Efficacy of sonically, ultrasonically and laser-activated irrigation in removing a biofilm-mimicking hydrogel from an isthmus model. Int Endod J. 2018. PMID: 30295328. doi:10.1111/iej.13024
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。