锥形束CT诊断根尖周炎的准确性:基于人类尸体的离体组织病理学研究
该研究以人类尸体颌骨标本的组织病理学为参考标准,评估锥形束CT(CBCT)诊断根尖周炎(AP)的准确性。样本包括223颗牙齿的340个牙根,涵盖所有牙组及不同疾病和治疗状态。结果显示,未根充牙的CBCT诊断准确性各指标均高,而根充牙各指标均较低,提示诊断准确性取决于牙齿的治疗状态。
要点
- 未根充牙CBCT诊断AP的敏感性、特异性、阳性预测值和阴性预测值均高。
- 根充牙CBCT诊断AP的各准确性指标均低于未根充牙。
- 将轻度AP归为AP时,根充牙的敏感性、特异性和阴性预测值显著降低(P < 0.001)。
核心结论
- CBCT诊断根尖周炎的准确性取决于牙齿的治疗状态。
- 未根充牙的CBCT诊断准确性高,几乎可正确诊断所有AP病例,过度诊断风险很小。
- 根充牙使用CBCT诊断AP的准确性较低,各诊断准确性参数均较低。
研究设计与样本
- 离体人类颌骨标本研究,以组织病理学为参考标准。
- 样本包括223颗牙齿的340个牙根,涵盖所有牙组及不同疾病和治疗状态。
- CBCT使用Cranex® 3Dx设备,小视野(5 × 5 cm),各向同性分辨率0.085 mm。
- 三名观察者使用概率指数评估AP的存在。
主要发现
- 未根充牙的所有诊断准确性估计值(敏感性、特异性、阳性预测值、阴性预测值)均高。
- 根充牙的所有诊断准确性估计值均较低。
- 当轻度AP归类为AP时,根充牙根的敏感性、特异性和阴性预测值均显著降低(P < 0.001)。
- 当轻度AP归类为无AP时,仅特异性差异显著(P < 0.001)。
临床怎么用
- 对于未根充牙,CBCT诊断AP准确性高,可可靠用于临床诊断。
- 对于根充牙,CBCT诊断AP准确性较低,解读结果需谨慎。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIM: To assess the diagnostic accuracy of Cone Beam Computed Tomography (CBCT) to diagnose apical periodontitis (AP) using histopathology of ex vivo human jaws as the reference standard. METHODOLOGY: Based on periapical radiographs of jaw specimens from human bodies donated for science, a sample of 223 teeth with 340 roots including all tooth groups, and different disease and treatment statuses was selected. Cone Beam Computed Tomography was performed using Cranex® 3Dx (Soredex Oy, Tuusula, Finland), small field-of-view (5 × 5 cm), and isotropic resolution 0.085 mm. Three observers assessed the presence of AP using a probability index. Histopathological examination of the periapical area was used as a reference standard to calculate estimates of diagnostic accuracy. RESULTS: For non-root filled teeth all estimates of diagnostic accuracy; sensitivity (SENS), specificity (SPEC), positive predictive value (PPV) and negative predictive value (NPV) were high. All estimates were lower for root filled teeth. When mild AP was classified as 'AP', SENS, SPEC and NPV were significantly lower in root filled roots (P < 0.001 in all cases). The same tendency was seen when mild AP was classified as 'No AP' but here only the difference in SPEC was significant (P < 0.001). CONCLUSION: The diagnostic accuracy of CBCT used for diagnosis of AP is dependent on the treatment status of the tooth. For non-root filled teeth the diagnostic accuracy of CBCT is high and almost all cases of AP can be diagnosed correctly with only a very small risk of over-diagnosis. All diagnostic accuracy parameters were lower for root filled roots, hence the diagnosis of AP on root filled roots using CBCT was less accurate.
引用
- Kruse C, Spin-Neto R, Evar Kraft DC, et al. Diagnostic accuracy of cone beam computed tomography used for assessment of apical periodontitis: an ex vivo histopathological study on human cadavers. Int Endod J. 2018. PMID: 30267421. doi:10.1111/iej.13020
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。