应用新型锥形束CT软件确定人恒牙根尖孔与邻面根面的位置关系
研究采用锥形束CT(CBCT)及新型影像分析软件e-Vol DX,对422例患者的1400颗恒牙进行根尖孔(AF)相对于根面的位置分析。结果显示上颌牙AF位于中央者占48.95%,下颌牙占42.08%,不同牙位AF位置分布各异,CBCT结合e-Vol DX可用于确定AF真实解剖位置并辅助牙髓治疗规划。
要点
- 上颌牙AF中央位占48.95%,下颌牙占42.08%。
- 下颌中切牙AF偏颊侧者占44%。
- CBCT结合e-Vol DX可辅助确定AF解剖位置。
核心结论
- 人恒牙根尖孔位于中央者上颌牙占48.95%、下颌牙占42.08%,CBCT结合e-Vol DX可确定AF真实解剖位置并辅助牙髓治疗规划。
研究设计与样本
- 采用CBCT扫描及e-Vol DX软件分析422例患者的1400颗恒牙,根据根面位置分类AF,并用卡方检验(Yates校正)分析分类变量,显著性水平α=0.05。
主要发现
- 上颌前牙AF最常见位于中央(46%-60%)。
- 下颌中切牙AF位于颊侧者占44%。
- 上颌第一和第二前磨牙AF位于中央者分别占39.98%和42.56%。
- 上颌第一和第二磨牙AF位于中央者分别占46.12%和57.49%。
- 下颌第一和第二前磨牙AF位于中央者分别占42.85%和50.98%,下颌第一磨牙AF位于中央者占48.72%。
临床怎么用
- CBCT影像经e-Vol DX分析可用于确定AF解剖位置,辅助非手术和手术牙髓治疗的治疗规划。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: The purpose of this study was to determine the position of the apical foramen (AF) in relation to root surfaces of human permanent teeth using cone-beam computed tomographic (CBCT) imaging and novel advanced imaging analysis software (e-Vol DX; CDT Software, Bauru, SP, Brazil). METHODS: The AF position was determined on CBCT scans viewed and analyzed using e-Vol DX of 1400 teeth (422 patients) according to the root surface as follows: buccal, mesiobuccal, mesial, mesiolingual/palatal, lingual/palatal, distolingual/palatal, distal, distobuccal, and central. Categoric variables were described as frequencies and percentages. Frequencies were reported with their confidence intervals (95%). Categoric variables were analyzed using the chi-square test with Yates correction. The level of significance was set at α = 0.05. RESULTS: The most frequent AF position in maxillary anterior teeth was central (46%-60%). The AF in mandibular central incisors was buccal in 44% of the cases. In maxillary first and second premolars, 39.98% and 42.56% of all AFs were central. In maxillary first and second molars, 46.12% and 57.49% of all AFs were central. The most frequent AF position in mandibular first and second premolars was central (42.85% and 50.98%). In mandibular first molars, 48.72% of all AFs were central. CONCLUSIONS: The AF position in human permanent teeth was central in 48.95% and 42.08% of the maxillary and mandibular teeth. CBCT images analyzed by e-Vol DX can be used to determine the true anatomic position of the AF and can be a useful tool for the treatment planning of nonsurgical and surgical endodontic treatments.
引用
- Estrela C, Couto GS, Bueno MR, et al. Apical Foramen Position in Relation to Proximal Root Surfaces of Human Permanent Teeth Determined by Using a New Cone-beam Computed Tomographic Software. J Endod. 2018. PMID: 30266469. doi:10.1016/j.joen.2018.07.028
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。