文献速递牙体牙髓病

不同髓腔入口屏障与漂白剂对根管治疗后前牙抗折性的影响

Effect of Different Intraorifice Barriers and Bleaching Agents on the Fracture Resistance of Endodontically Treated Anterior Teeth.
PubMed 文献 · J Endod · 2018-09-25

研究将72颗牛上颌切牙根管治疗后去除冠部3mm牙胶,按髓腔入口屏障分三组,再按漂白剂分四组,测量抗折性。漂白剂类型对抗折性影响显著(P<.05),屏障类型及交互作用不显著(P>.05);HP和PB组与对照组有显著差异(P<.05),CP组与对照组无显著差异(P>.05)。结论认为MTA和CEM与RMGI作为屏障效果相似,CP unlike HP和PB未显著降低抗折性。

要点

  • 漂白剂类型显著影响根管治疗后前牙的抗折性(P<.05)。
  • 髓腔入口屏障类型及与漂白剂的交互作用对抗折性无显著影响(P>.05)。
  • CP与对照组抗折性无显著差异,而HP和PB显著低于对照组(P<.05)。

核心结论

  • 矿物三氧化物凝聚体和富钙混合物作为髓腔入口屏障与树脂改性玻璃离子相似。
  • 过氧化脲不同于过氧化氢和过硼酸钠,未显著降低抗折性。

研究设计与样本

  • 研究对72颗拔除的牛上颌切牙进行根管治疗,去除冠部3mm牙胶。
  • 样本按髓腔入口屏障分为富钙混合物、矿物三氧化物凝聚体和树脂改性玻璃离子三组。
  • 每组再按漂白剂分为过氧化脲45%、过氧化氢35%、过硼酸钠和蒸馏水对照四个亚组。
  • 漂白后入口腔以复合树脂修复,用万能试验机以5 mm/min横梁速度测量抗折性。
  • 数据分析采用双因素方差分析和最小显著差事后检验(P<.05)。

主要发现

  • 漂白剂对抗折性的影响显著(P<.05)。
  • 髓腔入口屏障的影响及两因素交互作用不显著(P>.05)。
  • 过氧化氢和过硼酸钠组的抗折性与对照组有显著差异(P<.05)。
  • 过氧化脲组的抗折性与对照组无显著差异(P>.05)。

临床怎么用

  • 选择髓腔入口屏障时,矿物三氧化物凝聚体、富钙混合物和树脂改性玻璃离子均可考虑。
  • 使用过氧化氢或过硼酸钠漂白时需关注抗折性下降风险。
  • 过氧化脲对根管治疗后前牙抗折性影响较小。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: Intraorifice barriers (IOBs) are usually used before internal bleaching for coronal sealing and the prevention of cervical resorption. The aim of this study was to investigate the effect of different IOBs on the fracture resistance (FR) of endodontically treated anterior teeth bleached with various bleaching agents (BAs). METHODS: After performing root canal treatment for 72 extracted bovine upper incisors, the coronal 3 mm of gutta-percha was removed, and samples were classified into 3 based on the type of IOB: calcium-enriched mixture, mineral trioxide aggregate, and resin-modified glass ionomer. After applying IOBs, samples of each group were subdivided into 4 based on the BA: carbamide peroxide 45% (CP), hydrogen peroxide 35% (HP), sodium perborate (PB), and distilled water as the control. At the end of bleaching, the access cavities were restored with composite resin. The FR was measured with a universal testing machine at a crosshead speed of 5 mm/min. The data were analyzed using 2-way analysis of variance and least significant difference post hoc tests (P < .05). RESULTS: The effect of BAs on the FR was significant (P < .05); however, the effect of the IOB and the interactive effect of these variables were not significant (P > .05). The FR in the HP and PB groups was significantly different from the control (P < .05) but that of CP was not significantly different from the control (P > .05). CONCLUSIONS: Mineral trioxide aggregate and calcium-enriched mixture act similarly to resin-modified glass ionomer as an IOB. CP, unlike HP and PB, did not significantly decrease the FR.

来源:J Endod,查看原文。版权归原作者所有。

引用

  1. Oskoee SS, Bahari M, Daneshpooy M, et al. Effect of Different Intraorifice Barriers and Bleaching Agents on the Fracture Resistance of Endodontically Treated Anterior Teeth. J Endod. 2018. PMID: 30266467. doi:10.1016/j.joen.2018.07.025

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。