文献速递牙体牙髓病

离体牙切片模型评估牙髓对修复材料热及光固化反应

An ex-vivo model to determine dental pulp responses to heat and light-curing of dental restorative materials.
PubMed 文献 · J Dent · 2018-08-31

本研究开发离体牙切片模型,比较传统热电偶法与切片模型测量三种光固化单元所致温度升高,并进行组织形态学与免疫组化分析。传统法多数温度升高超过5.5°C,切片模型多数低于5.5°C;持续40秒的5.5°C以上温度升高导致细胞数立即减少,HSP70在6°C以上可检测到。

要点

  • 传统热电偶法高估光固化所致牙髓温度升高,应改用离体牙切片模型。
  • 持续40秒的5.5°C以上温度升高可致牙髓细胞数立即减少。
  • 5-7°C温度升高可能造成细胞损伤但不一定导致牙髓坏死。

核心结论

  • 评估光固化单元性能不应再使用实验室台面热电偶法测量温度升高。
  • 持续40秒的5.5°C以上温度升高导致细胞数立即减少,支持既往发现。
  • 5°C以下温度升高理想,但5-7°C间可能存在细胞损伤而不致牙髓死亡。

研究设计与样本

  • 离体牙切片模型与实验室台面热电偶法对照,测试三种常用光固化单元在不同照射时间和牙本质厚度下的温度升高。
  • 对切片模型进行组织形态计量和免疫组化(IL-1β、HSP70、caspase-3)分析。

主要发现

  • 牙本质厚度减少和照射时间增加导致温度升高。
  • 传统法60个记录点中53个温度升高超过5.5°C,切片模型60个参考点中52个低于5.5°C。
  • 持续40秒的5.5°C以上温度升高导致细胞数立即减少。
  • 所有样本未检测到IL-1β;温度升高6°C以上后立即检测到HSP70。
  • 温度升高7.5°C以上切片培养24小时后HSP70水平更高,并检测到低水平caspase-3。

关键数值与推荐

  • 牙髓温度升高不应超过5.5°C。
  • 持续40秒的5.5°C以上温度升高导致细胞数立即减少。
  • 温度升高6°C以上可立即检测到HSP70,7.5°C以上培养24小时后HSP70水平更高并出现低水平caspase-3。

临床怎么用

  • 临床应避免使用实验室台面热电偶法评估光固化单元产热。
  • 光固化操作应控制照射时间与牙本质厚度,尽量将牙髓温度升高控制在5°C以下。

局限性

  • 离体牙切片模型仍需进一步研究验证。
  • 免疫组化层面复杂相互作用提示5-7°C间可能存在细胞损伤但不一定导致牙髓死亡,需进一步研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIM: Based on histological studies from the 1960s, it is recommended that dental pulp temperature increases should not exceed 5.5 °C. However, no contemporary reliable models exist to explore the effects of heat on living dental pulp. The aim of this project was to develop a clinically valid model for studying temperature increases caused by three commonly-used light curing units (LCUs). METHODS: Temperature increases caused by LCUs at varying exposure times and via various thicknesses of dentine were recorded using traditional approaches (i.e. thermocouple device on a laboratory bench) and an ex-vivo tooth slice model. Histomorphometric and immunohistochemical (IL-1β, HSP70, caspase-3) analysis was performed of the tooth slice model following varying exposure and culture times. RESULTS: Reduced dentine thickness and increased exposure time led to increases in temperature. Whilst the majority of temperature increases recorded using the traditional approach (53 of 60) were greater than the recommended 5.5 °C, 52 of the 60 reference points recorded using the ex-vivo tooth slice model resulted in temperature increases of less than 5.5 °C. Temperature increases of 5.5 °C or more that are prolonged for 40 s caused an immediate decrease in cell number. IL-1β was not detected in any samples, while HSP70 was detectable immediately after exposure to a temperature increase of 6 °C or more. Higher levels of HSP70 were detected after 24 h culture in tooth slices that experienced a temperature increase of 7.5 °C or more. Low levels of caspase-3 were detected in tooth slices exposed to temperature increase of 7.5 °C or more. CONCLUSION: Experimental arrangements for assessing LCU performance that measure temperature increases using a thermocouple device on a laboratory bench should no longer be used. Future studies in this area should include replication of the clinical environment using greater sophistication, such as the use of an ex-vivo tooth slice model as described here. Temperature increases of 5.5 °C or more for 40 s caused an immediate decrease in cell number, which supports previous findings. However, complex interactions at an immunohistochemical level suggest that while temperature increases of 5 °C or less are ideal, there may be some cell damage between 5-7 °C which might not result in pulpal death. Further investigations are indicated.

来源:J Dent,查看原文。版权归原作者所有。

引用

  1. Lynch CD, Roberts JL, Al-Shehri A, et al. An ex-vivo model to determine dental pulp responses to heat and light-curing of dental restorative materials. J Dent. 2018. PMID: 30176259. doi:10.1016/j.jdent.2018.08.014

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。