文献速递牙体牙髓病

激光活化冲洗对下颌磨牙近中根管系统碎屑清除的体外比较

Debris Removal from the Mesial Root Canal System of Mandibular Molars with Laser-activated Irrigation.
PubMed 文献 · J Endod · 2018-09-18

INTRODUCTION: The purpose of this study was to compare in vitro the canal and isthmus debridement of manual-dynamic, passive ultrasonic, and laser-activated irrigation with an Er:YAG laser in mesial roots of human mandibular molars.…

要点

  • Er:YAG激光活化冲洗可显著提升根管与峡部碎屑清除效果。
  • 常规针头冲洗与手动动态冲洗对根管碎屑的减少不显著。
  • 所有冲洗方法均未能使根管系统达到完全无碎屑。

核心结论

  • 在体外条件下,冲洗活化能显著改善根管与峡部的清洁度。
  • 无一种冲洗方法能使根管系统完全无碎屑。

研究设计与样本

  • 分组为常规针头冲洗、手动动态冲洗、超声活化冲洗及Er:YAG激光活化冲洗。
  • 于最终冲洗前后拍摄根管横截面图像,用图像分析软件测定根管与峡部碎屑面积。

主要发现

  • 除常规针头冲洗和手动动态冲洗(仅根管)外,其余各组碎屑水平均显著降低。
  • 根管中,600-μm尖端置于根管入口外的Er:YAG激光活化冲洗碎屑清除显著多于常规针头冲洗。
  • 峡部中,400-μm锥形光纤尖端置于根管入口内的Er:YAG激光活化冲洗碎屑清除显著多于常规针头冲洗。

关键数值与推荐

  • Er:YAG激光活化冲洗采用400-μm锥形光纤尖端置于根管入口内或600-μm尖端置于根管入口外。

临床怎么用

  • 临床可考虑采用冲洗活化技术以改善下颌磨牙近中根管系统的碎屑清除。
  • Er:YAG激光活化冲洗可作为提升根管与峡部清洁度的可选方案。

局限性

  • 本研究为体外研究,结论受其设计局限。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: The purpose of this study was to compare in vitro the canal and isthmus debridement of manual-dynamic, passive ultrasonic, and laser-activated irrigation with an Er:YAG laser in mesial roots of human mandibular molars. METHODS: Fifty extracted mandibular molars with an isthmus were embedded in resin and sectioned axially 4 mm from the apex. The teeth were reassembled with guide pins and bolts, and the mesial canals were instrumented up to a ProTaper F2 rotary file (Dentsply Maillefer, Ballaigues, Switzerland). Teeth were randomly assigned to the following irrigant activation groups (n = 10): conventional needle irrigation (NI), manual-dynamic irrigation with a ProTaper F2 gutta-percha cone, ultrasonically activated irrigation using a size 20 Irrisafe (Satelec Acteon, Mérignac, France), and laser-activated irrigation (LAI) with an Er:YAG laser and a conical 400-μm fiber tip in the canal entrance or a 600-μm tip over the canal entrance. Root cross-sectional images were taken before and after final irrigation, and the area occupied by debris in the main canal and the isthmus was determined using image analysis software. Differences in debris before and after activation were statistically compared within and across groups. RESULTS: Significant reductions in debris levels were observed in all groups, except for NI and manual-dynamic irrigation (canal only). None of the methods rendered the canal systems debris free. In the canal, LAI with an Er:YAG laser and a 600-μm tip over the canal entrance removed significantly more debris than NI. In the isthmus, LAI with an Er:YAG laser and a conical 400-μm fiber tip in the canal entrance removed significantly more debris than NI. CONCLUSIONS: Within the limitations of this in vitro study, canal and isthmus cleanliness significantly improved after irrigant activation.

来源:J Endod,查看原文。版权归原作者所有。

引用

  1. Passalidou S, Calberson F, De Bruyne M, et al. Debris Removal from the Mesial Root Canal System of Mandibular Molars with Laser-activated Irrigation. J Endod. 2018. PMID: 30241679. doi:10.1016/j.joen.2018.06.007

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。