不同阻射性双抗生素糊剂的阻射性与抗菌性能
本研究评估含硫酸钡或氧化锆阻射剂的双抗生素糊剂(DAP)的阻射性和抗菌性能。结果显示,含硫酸钡的1 mg/mL DAP在残留抗菌效果上显著优于氢氧化钙,且阻射性相当。
要点
- 含硫酸钡或氧化锆的DAP阻射性与氢氧化钙无显著差异。
- 所有浓度DAP和氢氧化钙均显示直接抗菌效果。
- 1 mg/mL硫酸钡DAP残留抗菌效果显著优于氢氧化钙。
核心结论
- 1 mg/mL硫酸钡DAP具有显著更优的残留抗菌效果,且阻射性与氢氧化钙相当。
研究设计与样本
- 体外研究,评估不同浓度DAP的阻射性(每组n=6)和抗菌性(每组n=7)。
主要发现
- 所有测试浓度的硫酸钡DAP和氧化锆DAP的阻射性与氢氧化钙无显著差异。
- 所有测试浓度的硫酸钡DAP、氧化锆DAP和氢氧化钙均表现出显著的直接抗菌效果。
- 1 mg/mL氧化锆DAP和氢氧化钙未显示显著的残留抗菌效果。
关键数值与推荐
- 阻射性评估参照ISO 6876/2001标准(略作修改)。
- DAP浓度分别为1、10、25 mg/mL,含30% (w/v)硫酸钡或氧化锆。
- 抗菌实验使用厌氧感染3周的牙本质样本,处理1周后冲洗并进行生物膜破坏试验。
临床怎么用
- 1 mg/mL硫酸钡DAP可作为再生牙髓治疗中氢氧化钙的潜在替代品。
局限性
- 体外研究,结果需临床验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: We evaluated the radiopacity and antibacterial properties of various concentrations of double antibiotic paste (DAP) containing barium sulfate (BaSO4) or zirconium oxide (ZrO2) radiopaque agents. METHODS: The radiopacity of 1, 10, and 25 mg/mL DAP containing 30% (w/v) BaSO4 or ZrO2, DAP-free radiopaque pastes, and commercially available radiopaque calcium hydroxide (Ca[OH]2) were evaluated according to ISO 6876/2001 with slight modifications (n = 6 per group). Dentin samples (n = 70) infected anaerobically for 3 weeks with bacterial biofilms obtained from a root canal of an immature tooth with pulpal necrosis were treated with similar experimental pastes or received no treatment (n = 7). After 1 week, the pastes were rinsed off, and biofilm disruption assays were conducted. To show the residual antibacterial effects, sterile dentin samples (n = 70) were pretreated for 1 week with the same pastes (n = 7). The pastes were rinsed off, and the samples were immersed in phosphate-buffered saline for 24 hours and infected anaerobically with the same bacterial biofilm mentioned earlier for 3 weeks before conducting biofilm disruption assays. Sterile dentin blocks were used in both antibacterial analyses as negative control groups (n = 7). Wilcoxon rank sum tests were used for statistical analyses. RESULTS: No tested concentrations of BaSO4 DAP or ZrO2 DAP showed significant differences from Ca(OH)2 in radiopacity. However, all tested concentrations of BaSO4 DAP, ZrO2 DAP, and Ca(OH)2 exhibited significant direct antibacterial effects. ZrO2 DAP at 1 mg/mL and Ca(OH)2 did not show significant residual antibacterial effects. CONCLUSIONS: BaSO4 DAP at 1 mg/mL provided significantly superior residual antibacterial effects and comparable radiopacity with the commercially available Ca(OH)2.
引用
- Verma R, Fischer BI, Gregory RL, et al. The Radiopacity and Antimicrobial Properties of Different Radiopaque Double Antibiotic Pastes Used in Regenerative Endodontics. J Endod. 2018. PMID: 30078570. doi:10.1016/j.joen.2018.06.010
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。