文献速递牙体牙髓病

Reciproc Blue去除根管充填物及恢复根尖通畅的有效性

Effectiveness of Reciproc Blue in removing canal filling material and regaining apical patency.
PubMed 文献 · Int Endod J · 2018-09-08

本研究通过微计算机断层扫描(micro-CT)比较M-Wire Reciproc与Reciproc Blue器械去除根管充填物及恢复根尖通畅的能力。将10对解剖匹配的单根椭圆直根管牙预备并充填后随机分两组,分别用两种器械再治疗至25号和40号,评估残留充填物体积和表面积并记录时间。结果显示两组残留充填物无显著差异(P>0.05),根尖扩大至40号显著改善清除效果(P<0.05),所有样本均恢复根尖通畅,操作时间无差异。

要点

  • M-Wire Reciproc与Reciproc Blue去除椭圆直根管充填物效果相当。
  • 根尖扩大至40号较25号能显著提升充填物清除效果。
  • 两种器械再治疗均能恢复所有样本的根尖通畅。

核心结论

  • M-Wire Reciproc和Reciproc Blue均能有效去除椭圆直根管内的充填材料。
  • 所有样本在再治疗过程中均成功恢复根尖通畅。

研究设计与样本

  • 选取10对解剖匹配的单根椭圆直根管牙,经micro-CT扫描后预备并充填。
  • 随机分为M-Wire Reciproc组和Reciproc Blue组(每组n=10),再治疗至25号和40号。

主要发现

  • 两种器械在残留充填材料体积上无显著差异(P>0.05)。
  • 根尖扩大从25号至40号显著改善充填材料去除(P<0.05)。
  • 两组均能在所有样本中恢复根尖通畅。
  • 两种器械完成再治疗所需时间无差异。

关键数值与推荐

  • 残留充填材料体积比较采用t检验,显著性水平设为5%。
  • 再治疗过程中根管预备分别至25号和40号。

临床怎么用

  • 对于椭圆形直根管的再治疗,可选用M-Wire Reciproc或Reciproc Blue器械。
  • 适当扩大根尖至40号有助于更彻底地去除充填材料。

局限性

  • 研究仅纳入椭圆形直根管的离体牙,结果可能不适用于弯曲或复杂根管。
  • 样本量较小(每组10颗牙),统计效能有限。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIM: To compare the efficiency of M-Wire Reciproc and Reciproc Blue instruments in the removal of root filling material and in their ability to regain apical patency through micro-computed tomographic (micro-CT) analysis. METHODOLOGY: Ten anatomically matched pairs of teeth, with a single oval-shaped straight canal, were selected and scanned in a micro-CT device. The root canals were prepared with M-Wire Reciproc R25 instruments and filled with gutta-percha and AH Plus sealer. The root canals were then randomly allocated into two groups (n = 10), according to the instrument used: M-Wire Reciproc and Reciproc Blue. The canals were retreated up to instrument sizes 25 and then 40 in both groups. The surface area and volume of residual filling material were assessed using micro-CT imaging after the retreatment procedures. The time required to remove the root fillings was recorded. Data were analysed statistically using t-test with a significance level of 5%. RESULTS: No significant difference (P > 0.05) was observed between the instruments in terms of the volume of residual root filling material. Apical enlargement from size 25 to 40 significantly improved the removal of filling materials (P < 0.05). It was possible to regain apical patency in all specimens from both M-Wire Reciproc and Reciproc Blue groups. No difference was observed in the time required to perform the retreatment between the instruments. CONCLUSIONS: Both M-Wire Reciproc and Reciproc Blue instruments were effective in removing filling materials from oval-shaped straight canals. Apical patency was reestablished in all specimens.

来源:Int Endod J,查看原文。版权归原作者所有。

引用

  1. De-Deus G, Belladonna FG, Zuolo AS, et al. Effectiveness of Reciproc Blue in removing canal filling material and regaining apical patency. Int Endod J. 2018. PMID: 30091141. doi:10.1111/iej.12991

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。