单根锉系统与其匹配牙胶尖的直径和锥度变异性
本研究用光学显微镜测量F360和Reciproc各型号锉与匹配牙胶尖的直径和锥度。结果显示多数测量值在公差范围内,但锉与牙胶尖直径存在显著差异,冠端偏差最大,标准化仍有变异。
要点
- F360多数锉直径显著大于对应牙胶尖,但多数值在公差内。
- Reciproc冠端#25和#50锉直径显著小于牙胶尖。
- 两系统锥度几乎均匹配预设公差,但冠端直径偏差最大。
核心结论
- 尽管呼吁标准化,单根锉系统与其对应牙胶尖在直径和锥度尺寸上仍存在可预期的变异性。
主要发现
- F360多数锉和牙胶尖直径在公差水平内,但多数锉直径显著大于牙胶尖直径(P < .05)。
- Reciproc的D1和D3处锉与牙胶尖直径大多接近标称值。
- Reciproc冠端#25和#50锉直径显著小于牙胶尖直径(P < .05)。
- 两系统几乎所有锉和牙胶尖锥度均匹配预设公差范围。
- 冠端直径与标称值的百分比差异最高。
关键数值与推荐
- F360多数锉直径显著大于牙胶尖直径(P < .05)。
- Reciproc冠端#25和#50锉直径显著小于牙胶尖直径(P < .05)。
- 两系统几乎所有锉和牙胶尖锥度在预设公差范围内。
临床怎么用
- 临床选用单根锉及其匹配牙胶尖时,应意识到直径和锥度可能存在变异,尤其注意冠端尺寸差异。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: Manufacturers offer single-file instrumentation systems with matching gutta-percha (GP) cones to simplify root canal preparation and obturation. The purpose of this study was to determine whether file diameters and tapers match with corresponding cone diameters and tapers (precision) as well as industry standards (accuracy). METHODS: Twenty files and corresponding GP cones from each size of F360 (#25, #35, #45, #55 with .04 taper) and Reciproc (#25, #40, #50 with variable tapers) instruments were examined by using optical microscopy (×32) to determine their diameter and taper. Precision was evaluated by using one-way analysis of variance (α = 0.05) with Scheffé post hoc tests and t tests with Bonferroni correction. Accuracy was calculated by subtracting the nominal values from the measured values of all files and GP cones, and mean diameter and taper differences were compared by using one-way analysis of variance (α = 0.05) and Scheffé post hoc test for pairwise comparison. RESULTS: For F360, the majority of file and cone diameters were within the tolerance levels, but most of the file diameters were significantly larger than GP cone diameters (P < .05), but the majority of all measured values were within the tolerance levels. For Reciproc, file and cone diameters at D1 and D3 mostly approached the nominal values. At the coronal end, file diameters #25 and #50 were significantly smaller than cone diameters (P < .05). For both instrumentation systems, almost all file and cone tapers matched with the preset tolerance ranges. For Reciproc, significant differences between file and GP cone demonstrated either smaller cone or smaller file diameters and tapers, depending on the size. Most of the measured values were within the acceptable range, but diameters at the coronal end exhibited the highest percent difference from the nominal values. CONCLUSIONS: Despite the call for standardization, variability in diameter and taper dimensions between single-file instrumentation systems and their corresponding GP cones can be expected.
引用
- Haupt F, Seidel M, Rizk M, et al. Diameter and Taper Variability of Single-file Instrumentation Systems and Their Corresponding Gutta-percha Cones. J Endod. 2018. PMID: 30078573. doi:10.1016/j.joen.2018.06.005
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。