文献速递牙体牙髓病

模拟骨内正弦压力对次氯酸钠挤出影响

Effect of simulated intraosseous sinusoidal pressure on NaOCl extrusion.
PubMed 文献 · J Dent · 2018-08-02

本研究用仿真根管模型,比较有无30 mmHg模拟骨内正弦压力时,五种冲洗流速下2%次氯酸钠从根尖挤出的速率。结果显示挤出率与流速正相关,30 mmHg压力下各流速挤出率均显著降低;流速≤3.0 mL/min时侧方开口针头置于工作长度前1 mm可防止挤出。

要点

  • 次氯酸钠挤出率与冲洗流速正相关
  • 30 mmHg骨内压力下挤出率显著降低
  • 流速≤3.0 mL/min时侧方开口针头可防挤出

核心结论

  • 在30 mmHg模拟骨内正弦压力下,侧方开口针头置于工作长度前1 mm、流速≤3.0 mL/min时,次氯酸钠可能被防止挤出。

研究设计与样本

  • 体外仿真根管挤出实验,比较实验组(大气压+30 mmHg)与对照组(仅大气压),每组n=16。
  • 使用五种冲洗流速(15.6、8.0、4.0、3.4、3.0 mL/min)测量2%次氯酸钠从仿真根尖的挤出率。

主要发现

  • 无论有无模拟正弦压力,次氯酸钠挤出率均与冲洗流速正相关。
  • 除对照组4.0与3.4 mL/min两两比较外,所有流速间挤出率差异显著(p < 0.05)。
  • 所有冲洗流速下,30 mmHg模拟正弦压力组的挤出率均显著低于无对抗压力组(p < 0.05)。

关键数值与推荐

  • 模拟骨内压力为30 mmHg,冲洗液为2%次氯酸钠,针头为侧方开口针头置于工作长度前1 mm。
  • 流速≤3.0 mL/min时可能防止挤出。

临床怎么用

  • 临床使用侧方开口针头距工作长度1 mm冲洗时,可将流速控制在≤3.0 mL/min以降低次氯酸钠挤出风险。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: The present study examined the effects of irrigant flow rate and simulated intraosseous sinusoidal pressure on the rate of NaOCl extrusion from the apical terminus of a faux root canal. METHODS: An extrusion setup was designed to enable irrigant extrusion to be opposed by 30 mm Hg simulated intraosseous pressure. The faux canal apex was opposed by atmospheric + 30 mm Hg pressure (experimental) or atmospheric pressure only (control group). Using five irrigant delivery rates (15.6 8.0, 4.0, 3.4 or 3.0 mL/min), the extrusion rates of 2% NaOCl from the faux apex were measured in both groups (n = 16). Data were analysed with two-factor ANOVA and pairwise comparisons at α = 0.05. Correlation between NaOCl delivery rates and extrusion rates in both groups were analysed with the Pearson product-moment procedure. RESULT: Irrespective of the presence or absence of simulated sinusoidal pressure, NaOCl extrusion rates were positively-correlated with irrigant flow rates. For the factor "irrigant flow rates", significant differences in NaOCl extrusion rates were identified among all flow rates (p < 0.05), except for the pairwise comparison between 4.0 and 3.4 mL/min in the control. For all irrigant flow rates, NaOCl extrusion rate was significantly lower in the presence of 30 mm Hg simulated sinusoidal pressure than that obtained in the absence of opposing pressure (p < 0.05). CONCLUSION: In the presence of 30 mm Hg simulated intraosseous pressure, NaOCl delivered via a side-vented needle inserted to 1 mm short of working length may be prevented from extrusion when its flow rate is ≤ 3.0 mL/min. CLINICAL SIGNIFICANCE: When opposed by intraosseous sinusoidal pressure, NaOCl delivered via a side-vented needle inserted to 1 mm short of working length may be prevented from extrusion when its flow rate is ≤ 3.0 mL/min.

来源:J Dent,查看原文。版权归原作者所有。

引用

  1. Cai X, Wang XY, Santarcangelo F, et al. Effect of simulated intraosseous sinusoidal pressure on NaOCl extrusion. J Dent. 2018. PMID: 30077808. doi:10.1016/j.jdent.2018.08.001