文献速递牙体牙髓病

新型锥形束CT软件在术前工作长度测定中的准确性:离体研究

The Accuracy of a New Cone-beam Computed Tomographic Software in the Preoperative Working Length Determination Ex Vivo.
PubMed 文献 · J Endod · 2018-04-24

本研究用30颗前磨牙的锥形束CT扫描,比较3D Endo软件、传统CBCT软件和电子根尖定位仪在术前工作长度测定中的准确性。结果显示各方法均值无差异,3D-SL在根尖孔±0.5mm范围内的测量占86.6%,但电子根尖定位仪显著低估更少,3D软件显著超出根尖孔更少。结论是3D Endo可靠且与传统CBCT软件相似,但需联合电子根尖定位仪提高根尖孔定位准确性。

要点

  • 3D Endo软件术前工作长度测定可靠,与传统CBCT软件相似。
  • 3D-SL在根尖孔±0.5mm内占86.6%,3D-OL和EL占80%,CBCT长度占73.3%。
  • 建议CBCT联合电子根尖定位仪使用以提高根尖孔定位准确性。

核心结论

  • 使用3D Endo进行术前工作长度测定可靠,且与传统CBCT软件相似。
  • 联合使用CBCT与电子根尖定位仪可提高根尖孔定位的准确性。

研究设计与样本

  • 离体研究,对30颗前磨牙进行CBCT扫描。
  • 比较传统CBCT软件、3D Endo软件(含建议长度3D-SL和操作者调整长度3D-OL)与电子根尖定位仪Root ZX的测量值与实际长度。

主要发现

  • 各测量方法的均值无差异(方差分析,P > .05)。
  • 所有CBCT测量均呈现高可靠性(Dahlberg公式)。
  • 距根尖孔±0.5mm范围内的测量占比:3D-SL为86.6%,3D-OL和EL为80%,CBCT长度为73.3%。
  • 电子根尖定位仪显著减少低估测量(P < .05)。
  • 3D-OL和3D-SL显著减少超出根尖孔的测量(P < .05)。

临床怎么用

  • 术前可用3D Endo软件基于CBCT扫描测定工作长度,但应联合电子根尖定位仪以提高根尖孔定位准确性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: This study investigates the accuracy of 3D Endo software (Dentsply Sirona, Salzburg, Austria) to determine the working length when using preoperative cone-beam computed tomographic (CBCT) scans of extracted teeth, compared with conventional CBCT software and an electronic apex locator (EAL). METHODS: CBCT scans of 30 premolars were obtained. Using OnDemand3D software (Cybermed, Seoul, Korea), the measurement obtained from the coronal reference to the apical foramen (AF) was recorded as the conventional CBCT length. Then, using 3D Endo software (Dentsply Sirona), the suggested length (3D-SL) and the operator-adjusted length (3D-OL) were obtained. Teeth were accessed, and the actual length was measured. Finally, the teeth were embedded in alginate to obtain the electronic length (EL) using the EAL Root ZX (J Morita, Tokyo, Japan). The means of the absolute values and the percentages of distribution of the tested measurement methods were compared to the actual length. RESULTS: No difference was found regarding the mean measurements (analysis of variance, P > .05). All the CBCT measurements presented a high reliability (Dahlberg's formula). The measurements within a ±0.5-mm range from the AF were 86.6% for the 3D-SL, 80% for the 3D-OL and EL, and 73.3% for the CBCT length. The EL presented significantly fewer underestimated measurements (P < .05). The 3D-OL and 3D-SL presented significantly fewer measurements beyond the AF (P < .05). CONCLUSIONS: The preoperative working length determination using 3D Endo was reliable and similar to conventional CBCT software. However, the combined use of CBCT with an EAL is required to increase the accuracy in the location of the AF.

来源:J Endod,查看原文。版权归原作者所有。

引用

  1. Segato AVK, Piasecki L, Felipe Iparraguirre Nuñovero M, et al. The Accuracy of a New Cone-beam Computed Tomographic Software in the Preoperative Working Length Determination Ex Vivo. J Endod. 2018. PMID: 29703619. doi:10.1016/j.joen.2018.02.027

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。