一种表征锥形束CT图像中射束硬化伪影的新方法
本研究提出一种分别量化锥形束CT(CBCT)图像中射束硬化(BH)伪影亮、暗成分的新技术,并用3颗离体牙模型比较牙胶、锆基根充材料和氢氧化钙糊剂产生的伪影。结果显示锆基材料(K吸收边17.99 keV)比牙胶产生更小的暗伪影面积,且根冠三分之一伪影最大。
要点
- 锆基根充材料比牙胶产生更小的暗射束硬化伪影面积。
- 根冠三分之一的射束硬化伪影面积最大。
- 低K吸收边材料可减少根管全长射束硬化伪影。
核心结论
- 低K吸收边材料特性的根管充填材料可减少根管全长射束硬化伪影,并减少暗伪影的贡献。
研究设计与样本
- 离体牙模型研究,3颗模型牙的腭根管预备后分别充填牙胶、锆基根充材料和氢氧化钙糊剂,使用CS 9000 CBCT单位成像,ImageJ软件分别量化根管3个区域的亮、暗伪影面积,采用混合设计方差分析。
主要发现
- 所有充填材料之间及模型牙根所有区域之间暗伪影面积差异有统计学意义(P < .05)。
- 牙胶产生的暗伪影面积显著大于锆基材料(P < .05),但亮伪影面积无显著差异。
- 牙根所有区域之间亮、暗伪影面积差异均有统计学意义,根冠三分之一产生的伪影最大(P < .001)。
关键数值与推荐
- 锆基根充材料的K吸收边为17.99 keV。
- 暗伪影面积比较:牙胶 vs 锆基材料 P < .05。
- 根冠三分之一伪影最大 P < .001。
临床怎么用
- 选择低K吸收边的根管充填材料可能有助于减少CBCT图像中的射束硬化伪影。
- 评估根管充填后CBCT图像时应注意根冠三分之一伪影最明显。
局限性
- 研究仅使用3颗模型牙和单一CBCT单位,结果需进一步临床验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: The beam hardening (BH) artifact produced by root filling materials in cone-beam computed tomographic (CBCT) images is influenced by their radiologic K absorption edge values. The purpose of this study was to describe a novel technique to characterize BH artifacts in CBCT images produced by 3 root canal filling materials and to evaluate the effects of a zirconium (Zr)-based root filling material with a lower K edge (17.99 keV) on the production of BH artifacts. METHODS: The palatal root canals of 3 phantom model teeth were prepared and root filled with gutta-percha (GP), a Zr root filling material, and calcium hydroxide paste. Each phantom tooth was individually imaged using the CS 9000 CBCT unit (Carestream, Atlanta, GA). The "light" and "dark" components of the BH artifacts were quantified separately using ImageJ software (National Institutes of Health, Bethesda, MD) in 3 regions of the root. Mixed-design analysis of variance was used to evaluate differences in the artifact area for the light and dark elements of the BH artifacts. RESULTS: A statistically significant difference in the area of the dark portion of the BH artifact was found between all fill materials and in all regions of the phantom tooth root (P < .05). GP generated a significantly greater dark but not light artifact area compared with Zr (P < .05). Moreover, statistically significant differences between the areas of both the light and dark artifacts were observed within all regions of the tooth root, with the greatest artifact being generated in the coronal third of the root (P < .001). CONCLUSIONS: Root canal filling materials with lower K edge material properties reduce BH artifacts along the entire length of the root canal and reduce the contribution of the dark artifact.
引用
- Fox A, Basrani B, Kishen A, et al. A Novel Method for Characterizing Beam Hardening Artifacts in Cone-beam Computed Tomographic Images. J Endod. 2018. PMID: 29571911. doi:10.1016/j.joen.2018.02.005
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。