文献速递牙体牙髓病

三种镍钛器械根管预备时根尖碎屑推出量的体外研究

Apically Extruded Debris during Root Canal Instrumentation with Reciproc Blue, HyFlex EDM, and XP-endo Shaper Nickel-titanium Files.
PubMed 文献 · J Endod · 2018-03-15

本研究在35°C下比较Reciproc Blue、HyFlex EDM和XP-endo Shaper三种镍钛器械预备离体下颌前磨牙时根尖推出的碎屑量。XPS推出的碎屑显著少于REC Blue(P < .05),HEDM与其他两组差异均无统计学意义(P > .05)。

要点

  • 三种镍钛器械根管预备均会造成根尖碎屑推出。
  • XP-endo Shaper推出的碎屑量显著少于Reciproc Blue(P < .05)。
  • HyFlex EDM与其余两组的差异无统计学意义(P > .05)。

核心结论

  • 在本体外研究局限内,三种器械根尖推出碎屑量排序为REC Blue > HEDM > XPS,仅XPS与REC Blue间差异有统计学意义。

主要发现

  • 所有测试器械均从根尖孔推出一定量碎屑。
  • XPS推出的根尖碎屑显著少于REC Blue(P < .05)。
  • HEDM组与其他两组的差异均无统计学意义(P > .05)。

关键数值与推荐

  • 推出碎屑量通过预备后Eppendorf管重量减去无牙装置重量计算。
  • 数据采用Kruskal-Wallis检验,显著性水平为5%。

临床怎么用

  • 在需减少根尖碎屑推出的临床情境下,可优先考虑XPS而非REC Blue。

局限性

  • 本研究为体外研究,结论受其固有局限约束。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: The purpose of this study was to investigate the amount of apically extruded debris by Reciproc Blue (REC Blue; VDW, Munich, Germany), HyFlex EDM (HEDM; Coltene/Whaledent, Altstätten, Switzerland), and XP-endo Shaper (XPS; FKG Dentaire SA, La Chaux-de-Fonds, Switzerland) files during root canal preparation at body temperature. METHODS: Sixty extracted single-rooted mandibular premolar human teeth were randomly assigned to 3 groups (n = 20). The canals were instrumented using 1 of the following instruments: REC Blue, HEDM, or XPS. Apically extruded debris during instrumentation was collected into preweighed Eppendorf tubes. All the procedures were performed at 35°C. The amount of extruded debris was calculated by subtracting the weight value of the tooth-free apparatus from the postpreparation weight value. The data were analyzed using the Kruskal-Wallis test at a 5% significance level. RESULTS: All the instruments tested caused extrusion of some debris from the apical foramen. XPS extruded significantly less debris from the apex than REC Blue (P < .05). The difference among the HEDM group and the other groups was not significant (P > .05). CONCLUSIONS: Within the limitations of this in vitro study, the amount of apically extruded debris registered for the different files tested was REC Blue > HEDM > XPS, with a statistical difference only between XPS and REC Blue.

来源:J Endod,查看原文。版权归原作者所有。

引用

  1. Uslu G, Özyürek T, Yılmaz K, et al. Apically Extruded Debris during Root Canal Instrumentation with Reciproc Blue, HyFlex EDM, and XP-endo Shaper Nickel-titanium Files. J Endod. 2018. PMID: 29550013. doi:10.1016/j.joen.2018.01.018

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。