氩等离子体活化种植体周围硬软组织变化的组织形态计量学研究
本研究在8只犬的下颌骨植入经氩等离子体清洗活化的钛种植体(试验组)与未处理种植体(对照组),分别于愈合1个月和2个月进行组织学评估。愈合2个月时试验组新骨形成及总矿化骨比例显著高于对照组,提示氩等离子体处理可提高骨-种植体接触。
核心结论
- 氩等离子体处理的种植体相比未处理种植体可获得更高的骨-种植体接触。
研究设计与样本
- 采用犬动物实验,共纳入8只犬,下颌前磨牙及第一磨牙拔除后植入ZirTi表面种植体(长7 mm、直径3.3 mm),每侧半颌4枚,随机分为氩等离子体处理组与未处理组,自身对照设计,分别于1个月和2个月进行组织学评估。
临床怎么用
- 氩等离子体处理可能作为提升种植体早期骨结合的一种表面处理策略,但需结合临床进一步验证。
局限性
- 本研究为犬动物实验,样本量有限(8只犬),结果外推至人类临床需谨慎。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To histologically assess the hard and soft tissue changes after insertion of cleaned and activated titanium implants using plasma of argon. MATERIALS AND METHODS: Eight dogs were included in this study. The mandibular premolars and first molars were extracted. For each hemi-mandible, four implants, 7 mm long and 3.3 mm of diameter, with a ZirTi surface were used. The surface of two implants was randomly treated with argon plasma (test), while the other two implants were left untreated (control). After 1 month, the same procedure was performed in the contralateral hemi-mandible. The amount of old bone, new bone, overall value of old bone plus new bone, and soft tissue was histologically evaluated. RESULTS: After 1 month of healing, high percentages of new bone in close contact with the implant surface were found at both the treated (60.1% ± 15.6%; 95% CI 56.5%-78.0%) and untreated (57.2% ± 13.1%; 95% CI 49.3%-67.5%) implants. Low percentages of old bone were found at this stage of healing, at both the treated (4.4% ± 3.0%; 95% CI 1.2%-5.4%) and untreated (3.4% ± 3.1%; 95% CI 0.6%-4.9%) implants. Not statistically significant differences were found between groups (p > .05). After 2 months of healing, treated implants presented a significantly higher (p = .012) new bone formation (72.5% ± 12.4%; 95% CI 69.6%-86.8%) compared to untreated sites (64.7% ± 17.3%; 95% CI 59.4%-83.3%). Controversially, no difference (p = .270) in terms of old bone was present between treated (3.1% ± 1.7%, 95% CI 1.8%-4.2%) and untreated implants (3.8% ± 1.9%, 95% CI 3.2%-5.8%). Significant differences (p = .018) in terms of total mineralized bone were found between treated (75.6% ± 13.0%, 95% CI 73.3%-91.3%) and untreated implants (68.4% ± 16.8%; 95% CI 64.2%-87.6%). CONCLUSIONS: Implants treated using plasma of argon was demonstrated to reach a higher bone-to-implant contact when compared to untreated implants.
引用
- Canullo L, Tallarico M, Botticelli D, et al. Hard and soft tissue changes around implants activated using plasma of argon: A histomorphometric study in dog. Clin Oral Implants Res. 2018. PMID: 29453788. doi:10.1111/clr.13134
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。