偏质量旋转镍钛器械对下颌第一磨牙根管成形效果的micro-CT研究
本研究采用micro-CT评估两种偏质量旋转镍钛器械(ProTaper Next、Revo-S)与常规中心质量旋转器械(ProTaper Universal)在下颌第一磨牙根管成形中的效果。结果显示偏质量器械在根尖1mm处偏移更小、居中度更好,所有器械均增加根管面积和体积且组间无显著差异。
要点
- 偏质量旋转器械在根尖1mm处偏移显著小于中心质量器械。
- 三组器械均增加根管面积、体积和SMI,组间无显著差异。
- 偏质量器械在根尖1mm处居中度优于中心质量器械。
核心结论
- 无论横截面设计、合金类型和锥度变化如何,偏质量旋转器械比中心质量旋转器械表现出更好的根管成形能力。
研究设计与样本
- 使用SkyScan 1272扫描仪在10-μm各向同性分辨率下于预备前后扫描标本。
主要发现
- 在距根尖孔1mm处,PTN和RS系统相比PTU系统显示显著更小的偏移和更好的居中度(P < .05)。
- 所有器械均增加根管面积、体积和SMI值,但三组间无显著差异(P > .05)。
关键数值与推荐
- 近中根管根尖预备使用PTN X2(#25/0.06)、RS SU(#25/0.06)和PTU F2(#25/0.08)。
- 远中根管根尖预备使用PTN X3(#30/0.07)、RS AS30(#30/0.06)和PTU F3(#30/0.09)。
- 在距根尖孔1、3、5、7mm处测量根管偏移和居中度。
- 数据分析采用单因素方差分析和Tukey事后检验。
临床怎么用
- 对于下颌第一磨牙根管成形,偏质量旋转器械可能减少根尖1mm处的偏移并提高居中度。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: The aim of this study was to evaluate the root canal shaping effect of 2 nickel-titanium rotary instruments with offset mass of rotation compared with an instrument with a conventional centered mass of rotation. METHODS: Thirty-six extracted human mandibular first molars with 2 independent mesial canals and 1 oval distal canal were selected and divided equally into 3 groups for instrumentation with ProTaper Next (PTN; Dentsply Maillefer, Ballaigues, Switzerland), Revo-S (RS; Micro-Mega, Besançon, France), and ProTaper Universal (PTU, Dentsply Maillefer) systems (n = 12). For apical preparation, PTN X2 (#25/0.06), RS SU (#25/0.06), and PTU F2 (#25/0.08) were used in the mesial canals and PTN X3 (#30/0.07), RS AS30 (#30/0.06), and PTU F3 (#30/0.09) were used in the distal canals. Specimens were scanned before and after instrumentation using a SkyScan 1272 scanner (Bruker micro-CT, Kontich, Belgium) at 10-μm isotropic resolution. Changes in the canal area, volume, structure model index (SMI), and untouched canal area were evaluated. Canal transportation and centering ratio were measured at 1, 3, 5, and 7 mm from the apical foramen. Data were statistically analyzed using 1-way analysis of variance with the Tukey post hoc test. RESULTS: The PTN and RS systems showed significantly less transportation and better centering ability compared with the PTU system at 1 mm from the apical foramen (P < .05). All instrumentation increased the canal area, volume, and SMI values without significant differences among the 3 groups (P > .05). CONCLUSIONS: Regardless of the differences in the cross-sectional design, alloy type, and taper variation, instruments with offset mass of rotation showed better root canal shaping ability compared with an instrument with a centered mass of rotation.
引用
- Kyaw Moe MM, Ha JH, Jin MU, et al. Root Canal Shaping Effect of Instruments with Offset Mass of Rotation in the Mandibular First Molar: A Micro-computed Tomographic Study. J Endod. 2018. PMID: 29398088. doi:10.1016/j.joen.2017.11.012
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。