ProTaper再治疗系统去除弯曲根管内三种充填材料的微CT评价
该离体研究用micro-CT评价ProTaper Universal Retreatment器械去除Thermafil、GuttaCore或垂直加压牙胶的疗效。60颗弯曲磨牙根管预备至30号.04锥度并充填后行再治疗,残留充填材料14.2-19.3%、牙本质去除2.7-3.2 mm3,各组间无显著差异;GuttaCore组到达工作长度显著更快;60个根管中5个发生侧穿(8%)。
要点
- 三种充填技术再治疗后残留材料与牙本质去除量无显著差异。
- GuttaCore组到达工作长度的时间显著短于Thermafil和垂直加压组。
- ProTaper再治疗弯曲根管时侧穿发生率为8%(5/60)。
核心结论
- 三种充填技术的残留充填材料和牙本质去除量相似。
- GuttaCore组重新到达工作长度显著快于Thermafil和垂直加压牙胶组。
- 使用ProTaper Universal Retreatment器械再治疗重度弯曲根管时,60个根管中5个(8%)发生操作失误。
研究设计与样本
- 离体研究,选用60颗弯曲磨牙牙根,两个方向上的平均根管弯曲度和半径相同。
- 样本用ProFile器械预备至30号.04锥度,分别以Thermafil、GuttaCore或垂直加压牙胶加AH Plus充填,每组n=20。
- 用ProTaper Universal Retreatment D1、D2、D3器械至工作长度再治疗,再用ProTaper Next预备至×4。
- 用micro-CT评估残留充填材料百分比和牙本质去除量,记录操作时间和操作失误,采用Kruskal-Wallis和Wilcoxon检验。
主要发现
- 载体基与热垂直加压充填在残留充填材料(14.2-19.3%)和牙本质去除量(2.7-3.2 mm3)方面无显著差异(P > 0.05)。
- GuttaCore组到达工作长度的时间显著快于Thermafil和垂直加压组(P < 0.05)。
- 再治疗过程中D3器械发生5例侧穿,Thermafil组1例,垂直加压组4例。
临床怎么用
- 对弯曲根管再治疗时,三种充填技术的残留材料和牙本质去除效果相当。
- 若追求更快到达工作长度,GuttaCore充填的根管可能更有优势。
- 使用ProTaper再治疗弯曲根管时需警惕侧穿风险,本研究中发生率为8%。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIM: To evaluate ex vivo the efficacy of ProTaper Universal Retreatment files (Dentsply Sirona, Ballaigues, Switzerland) in removing Thermafil, GuttaCore (both Dentsply Sirona) or vertically compacted gutta-percha from curved root canals using micro-CT. METHODOLOGY: Sixty curved molar roots with the same mean canal curvatures and radii in two directions were prepared using ProFile instruments (Dentsply Sirona) to size 30 with .04 taper and obturated with either Thermafil, GuttaCore or vertically compacted gutta-percha and AH Plus (n = 20). Specimens were retreated using the ProTaper Universal Retreatment files D1, D2 and D3 to working length, and root canal preparation was completed with ProTaper Next (Dentsply Sirona) to size ×4. Percentages of residual filling material and dentine removal were assessed using micro-CT imaging. Working time and procedural errors were recorded. Statistical analysis was performed using Kruskal-Wallis and Wilcoxon tests. RESULTS: No significant differences between carrier-based and warm vertical compaction regarding residual filling material (14.2-19.3%) and dentine removal (2.7-3.2 mm3 ) were detected (P > 0.05). Time to reach working length was significantly faster for canals filled with GuttaCore than that observed for Thermafil and warm vertical compaction (P < 0.05). Five lateral perforations with the D3 file occurred during retreatment, one in the Thermafil and four in the vertical compaction group. CONCLUSIONS: Remaining filling material and dentine removal were similar for all canal filling techniques. Regaining working length was significantly faster for GuttaCore compared with Thermafil and vertically compacted gutta-percha. Procedural errors occurred during retreatment of severely curved root canals with the ProTaper Universal Retreatment files in 5 of 60 canals (8%).
引用
- Rödig T, Wagner J, Wiegand A, et al. Efficacy of the ProTaper retreatment system in removing Thermafil, GuttaCore or vertically compacted gutta-percha from curved root canals assessed by micro-CT. Int Endod J. 2018. PMID: 29363142. doi:10.1111/iej.12893
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。