四种根尖倒充填材料间隙体积的微计算机断层扫描比较
本研究用微计算机断层扫描比较四种根尖倒充填材料与牙本质间的间隙体积百分比。ProRoot MTA组间隙体积百分比中位数最大,与其他组差异有统计学意义(P < .05)。
要点
- ProRoot MTA的间隙体积百分比高于MTA Angelus、EndoCem MTA和RetroMTA。
- 微计算机断层扫描可三维定量评估根尖倒充填材料与牙本质的间隙。
- 各组间隙体积百分比中位数均较低,但ProRoot MTA组差异有统计学意义。
核心结论
- 微计算机断层扫描分析显示,ProRoot MTA的间隙体积百分比大于其他根尖倒充填材料。
主要发现
- ProRoot MTA、MTA Angelus、EndoCem MTA和RetroMTA组间隙体积百分比中位数分别为0.00472、0.00134、0.00014和0.00071。
- ProRoot MTA组间隙体积百分比最大,与其他组差异有统计学意义(P < .05)。
关键数值与推荐
- 间隙体积百分比为牙本质壁与根尖倒充填材料之间间隙体积占百分比,由微计算机断层扫描三维重建测量。
- 数据用Kruskal-Wallis和Mann-Whitney U检验分析,显著性水平为95%。
临床怎么用
- 选择根尖倒充填材料时可参考间隙体积百分比,ProRoot MTA在该体外模型中间隙体积百分比较其他三种材料大。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: The purpose of this study was to evaluate the gap volume between dentin and root-end filling materials. METHODS: Four root-end filling materials were compared in the present study: ProRoot MTA (PRM; Dentsply Tulsa Dental, Tulsa, OK), MTA Angelus (MAG; Angelus, Londrina, Brazil), EndoCem MTA (ECM; Maruchi, Wonju, Korea), and RetroMTA (RTM; BioMTA, Seoul, Korea). Forty-eight single-rooted, extracted human teeth were instrumented with nickel-titanium instruments and oburated with gutta-percha. The apical 3 mm of the root tip was resected, and root-end preparation was performed with a diamond bur. The root-end cavity was filled with the experimental filling materials for the 4 designated groups (n = 10). Then, the samples were scanned with micro-computed tomographic (micro-CT) imaging. Three-dimensional images of the samples were reconstructed, and the volume of the gap between the tooth surface (dentinal wall) and the root-end filling materials was measured. The percentage volume of the gap between the tooth structure and the root-end filling material (VG%) was calculated. Data were analyzed using the Kruskal-Wallis and Mann-Whitney U tests at a significance level of 95%. RESULTS: The median VG% values for the PRM, MAG, ECM, and RTM groups were 0.00472, 0.00134, 0.00014, and 0.00071, respectively. The ProRoot MTA group showed the greatest gap volume percentage among the experimental groups with a significant statistical difference (P < .05). CONCLUSIONS: From the micro-CT analysis, ProRoot MTA had a greater gap volume percentage than other root-end filling materials.
引用
- Kim SY, Kim HC, Shin SJ, et al. Comparison of Gap Volume after Retrofilling Using 4 Different Filling Materials: Evaluation by Micro-computed Tomography. J Endod. 2018. PMID: 29306529. doi:10.1016/j.joen.2017.11.009
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。