两种硅酸钙与玻璃离子水门汀和根尖牙本质间的边缘间隙比较
研究比较Biodentine、MTA+和Fuji IX三种材料倒充填后与根管牙本质间的边缘间隙。采用接触角测润湿性、压汞法和显微CT测孔隙率,并对离体上颌切牙倒充填后显微CT计算间隙体积。结果显示Biodentine微间隙最低,Biodentine与MTA在倒充填密封性上优于Fuji IX。
要点
- Biodentine的微间隙最低,为(10±30)×10⁻³ mm³。
- Biodentine微孔隙率最低,SBF浸泡前后分别为1.2%和0.8%。
- Fuji IX纳米孔隙率最低但微孔隙率最高,密封性不及Biodentine和MTA。
核心结论
- Biodentine和MTA在倒充填根管的密封性上优于Fuji IX。
- Biodentine在水门汀-牙本质界面呈现最低边缘间隙的趋势。
研究设计与样本
- 离体人上颌切牙倒充填后,用显微CT计算充填材料与根管牙本质间的间隙体积。
- 测量材料接触角评估润湿性,用压汞法和显微CT测定孔隙率,实验在模拟体液浸泡前后进行。
主要发现
- 模拟体液浸泡后,各材料接触角间无统计学显著差异。
- Fuji IX纳米孔隙率最低(SBF前后分别为2.99%和4.17%),但微孔隙率最高(SBF前后分别为4.2%和3.1%)。
- Biodentine微孔隙率最低(SBF前后分别为1.2%和0.8%),微间隙也最低([10±30]×10⁻³ mm³)。
临床怎么用
- 根尖手术倒充填可优先考虑Biodentine或MTA以获得更严密的封闭。
- Fuji IX虽纳米孔隙率低,但微孔隙率较高且边缘间隙较大,密封性相对不足。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: The outcome of periapical surgery has been directly improved with the introduction of novel material formulations. The aim of the study was to compare the retrograde obturation quality of the following materials: calcium silicate (Biodentine; Septodont, Saint-Maur-des-Fosses, France), mineral trioxide aggregate (MTA+; Cerkamed Company, Stalowa Wola, Poland), and glass ionomer cement (Fuji IX; GC Corporation, Tokyo, Japan). METHODS: Materials' wettability was calculated concerning the contact angles of the cements measured using a glycerol drop. Cements' porosity was determined using mercury intrusion porosimetry and micro-computed tomographic (μCT) imaging. Extracted upper human incisors were retrofilled, and μCT analysis was applied to calculate the volume of the gap between the retrograde filling material and root canal dentin. Experiments were performed before and after soaking the materials in simulated body fluid (SBF). RESULTS: No statistically significant differences were found among the contact angles of the studied materials after being soaked in SBF. The material with the lowest nanoporosity (Fuji IX: 2.99% and 4.17% before and after SBF, respectively) showed the highest values of microporosity (4.2% and 3.1% before and after SBF, respectively). Biodentine had the lowest value of microporosity (1.2% and 0.8% before and after SBF, respectively) and the lowest value of microgap to the root canal wall ([10 ± 30] × 10-3 mm3). CONCLUSIONS: Biodentine and MTA possess certain advantages over Fuji IX for hermetic obturation of retrograde root canals. Biodentine shows a tendency toward the lowest marginal gap at the cement-to-dentin interface.
引用
- Biočanin V, Antonijević Đ, Poštić S, et al. Marginal Gaps between 2 Calcium Silicate and Glass Ionomer Cements and Apical Root Dentin. J Endod. 2018. PMID: 29336880. doi:10.1016/j.joen.2017.09.022
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。