评估根管冲洗与声波搅拌后抗生物膜效果的生物膜检测方法验证
结果显示冲洗后细菌减少显著(P < .001),声波搅拌进一步降低活细胞比例(P < .05)但未能完全清除生物膜,强调结合多种方法综合评估的必要性。
要点
- 培养法与qRT-PCR在冲洗前样本中均显示约8-log CFU的细菌量。
- 次氯酸钠联合EDTA冲洗及附加声波搅拌均显著降低细菌量和相对发光值(P < .001)。
- 声波搅拌显著降低活细胞比例(P < .05),但未能消除生物膜结构。
核心结论
- 器械预备联合注射器冲洗可实现最大程度的微生物减少。
- 附加声波搅拌可进一步减少根管生物膜,但不能在单根管模型中完全清除生物膜。
- 强调结合微生物学与分子定量方法及CLSM综合评估根管抗生物膜效果的价值。
研究设计与样本
- 所有根管均采用F3 ProTaper Universal器械预备,并使用ProRinse针头冲洗。
- 组1:次氯酸钠和EDTA冲洗;组2:附加声波搅拌NaOCl;组3:无菌蒸馏水冲洗。
- 在预备前(S1)和预备后(S2)采集细菌样本,采用培养法、qRT-PCR和luminescence法定量。
- 通过SEM和CLSM评估生物膜结构和细菌细胞活力,统计学显著性设定为P < .05。
主要发现
- S1样本中培养法和qRT-PCR均显示约8-log colony-forming-units的细菌。
- 组1和组2的S2样本中细菌种群减少和相对发光值降低均高度显著(P < .001)。
- SEM和CLSM显示预处理样本中存在成熟根管生物膜,处理后减少。
- NaOCl冲洗联合声波搅拌显著降低活细胞百分比(P < .05),但未能消除生物膜结构。
临床怎么用
- 临床可采用器械预备联合注射器冲洗作为基础方案,声波搅拌可作为辅助手段进一步减少生物膜。
- 评估根管抗生物膜效果时,建议结合微生物培养、分子定量和CLSM等多方法综合判断。
局限性
- 研究采用离体单根牙模型,结果可能不能完全推广至临床复杂根管系统。
- 声波搅拌虽进一步减少生物膜,但未能完全清除,提示单一辅助方法存在局限。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: Different methods to characterize bacterial biofilms have been established, each presenting with distinct advantages and shortcomings. The aim of this study was to validate the ability of microbiological culture, the adenosine-5'-triphosphate (luminescence) assay, molecular, and microscopic methods to assess antibiofilm efficacy. METHODS: Thirty-nine extracted single-rooted teeth were selected. Enterococcus faecalis biofilms were grown for 21 days and randomly distributed into 3 groups. All canals were instrumented (F3 ProTaper Universal; Dentsply Sirona, Johnson City, TN) and irrigated (ProRinse needles, Dentsply Sirona) as follows: group 1, sodium hypochlorite and EDTA irrigation; group 2, supplemented with sonic agitation of NaOCl, and group 3, sterile distilled water irrigation. Bacteriologic samples were collected before (S1) and after canal preparation (S2) and subjected to quantification by culture methods, quantitative reverse transcriptase real-time PCR (qRT-PCR), and luminescence assay. The biofilm structure and bacterial cell viability were evaluated under scanning electron microscopy (SEM) and confocal laser scanning microscopy (CLSM). Data were subjected to statistical analysis to determine the statistical significance (P < .05). RESULTS: S1 samples showed approximately 8-log colony-forming-units of bacteria using both culture and qRT-PCR. The reduction in bacterial population and relative luminescence was highly significant in the S2 samples from groups 1 and 2 (P < .001). SEM and CLSM showed well-matured root canal biofilms in the pretreatment samples that were reduced after treatment. Irrigation with NaOCl combined with sonic agitation significantly decreased the percentage of live cells (P < .05) but was not able to eliminate the biofilm structure. CONCLUSIONS: This study highlighted the maximum reduction of microbes after instrumentation-syringe irrigation. Although supplementary sonic agitation reduced the root canal biofilm further, it did not completely eliminate the biofilm from a single root canal model. The merits of combining microbiological and molecular quantification methods with CLSM for the comprehensive assessment of antibiofilm efficacy in root canals were emphasized.
引用
- Kishen A, Shrestha A, Del Carpio-Perochena A, et al. Validation of Biofilm Assays to Assess Antibiofilm Efficacy in Instrumented Root Canals after Syringe Irrigation and Sonic Agitation. J Endod. 2017. PMID: 29254815. doi:10.1016/j.joen.2017.10.005
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。