Mani GPR与HyFlex NT去除弯曲根管充填物后辅以被动超声冲洗的比较
本研究比较HyFlex NT与Mani GPR系统在再治疗中去除弯曲根管充填物的效果,并对残留材料辅以被动超声冲洗(PUI)。20颗离体下颌磨牙的40个近中根管随机交替使用两种系统,micro-CT评估充填物去除率并记录操作时间。两种系统去除率相似(95.5%与92.7%,P>.05),Mani GPR用时更短(P<.05),PUI显著提升去除效果(P<.05)。
要点
- Mani GPR与HyFlex NT去除弯曲根管充填物的百分比相似。
- Mani GPR去除充填材料的操作时间显著短于HyFlex NT。
- 辅以被动超声冲洗可显著提高充填材料去除效果。
核心结论
- 两种系统在再治疗中去除根管充填物的效果相当,Mani GPR操作更快。
- 辅以被动超声冲洗可显著改善充填材料去除效果。
研究设计与样本
- 采用20颗离体下颌磨牙的40个近中根管(Vertucci IV型),随机交替使用HyFlex NT或Mani GPR进行再治疗。
- 两种系统最终预备尺寸均为40/0.04,用micro-CT评估再治疗前后充填物体积并记录操作时间。
- 对仍有充填物残留的根管辅以被动超声冲洗,再次进行micro-CT扫描。
主要发现
- Mani GPR与HyFlex NT去除充填材料的百分比分别为95.5%和92.7%,差异无统计学意义(P>.05)。
- Mani GPR去除充填材料所需时间显著少于HyFlex NT(P<.05)。
- 辅以被动超声冲洗显著提高了充填材料的去除效果(P<.05)。
临床怎么用
- 再治疗去除弯曲根管充填物时,Mani GPR与HyFlex NT均可选择,Mani GPR更省时。
- 对残留充填物可辅以被动超声冲洗以提升清除效果。
局限性
- 研究为离体牙实验,样本量有限(20颗牙,40个根管)。
- 仅评估下颌磨牙近中根管Vertucci IV型,结果外推需谨慎。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
This study compared the efficacy of HyFlex NT (HF; Coltene, New York, NY) and Mani GPR (MN; Mani Inc, Tokyo, Japan) systems followed by a supplementary approach with passive ultrasonic irrigation (PUI) in removing the filling material from curved root canals during retreatment. The mesial canals from 20 extracted mandibular molars with Vertucci type IV configuration were instrumented and obturated (N = 40). Each mesial canal was retreated using either HF or MN instruments, alternating the system used per canal from root to root. The final preparation size was 40/0.04 for both systems. The volume of canal filling material was assessed by means of micro-computed tomographic (micro-CT) imaging before and after retreatment, and the working time was recorded. Canals still showing remnants of filling material were subjected to a supplementary approach with PUI, and another micro-CT scan was taken. The percentage of filling material removed with MN instruments and HF was similar (95.5% and 92.7%, respectively) (P > .05). MN required significantly less time to remove the filling material (P < .05). The supplementary approach with PUI significantly enhanced the removal of filling material (P < .05). Both systems were equally effective in removing the root canal filling during retreatment. MN was faster than HF. The supplementary approach with PUI significantly improved filling material removal.
引用
- Silveira SB, Alves FRF, Marceliano-Alves MF, et al. Removal of Root Canal Fillings in Curved Canals Using Either Mani GPR or HyFlex NT Followed by Passive Ultrasonic Irrigation. J Endod. 2017. PMID: 29254819. doi:10.1016/j.joen.2017.09.012
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。