文献速递牙体牙髓病

新型根管封闭剂理化性能的评估

Evaluation of Physicochemical Properties of a New Root Canal Sealer.
PubMed 文献 · J Endod · 2017-12-16

本研究比较新型根管封闭剂Sealer Plus与AH Plus的理化性能,依据ANSI/ADA No.57和ISO 6876标准测试。结果显示Sealer Plus的阻射性低于AH Plus但仍高于标准最低值,流动性和溶解度无显著差异,初凝和终凝时间显著短于AH Plus,两者pH均无显著升高。结论为Sealer Plus的理化性能符合相关标准。

要点

  • Sealer Plus阻射性低于AH Plus但高于标准最低值3 mm Al。
  • Sealer Plus初凝138分钟、终凝210分钟,均短于AH Plus。
  • 两种封闭剂流动性和溶解度无显著差异,pH均无显著升高。

核心结论

  • Sealer Plus封闭剂的理化性能符合ANSI/ADA No.57(2000)和ISO 6876(2012)标准。

研究设计与样本

  • 体外研究比较Sealer Plus与AH Plus的理化性能,依据ANSI/ADA No.57和ISO 6876标准测试阻射性、流动性、溶解度和凝固时间。
  • 初凝和终凝时间采用ASTM C266/2008标准测量,pH在3、24、72和168小时评估,统计显著性水平为5%。

主要发现

  • Sealer Plus的阻射性低于AH Plus(P < .05),但高于标准推荐最低值3 mm Al。
  • Sealer Plus流动性为19.19 mm,AH Plus为19.81 mm(P > .05)。
  • Sealer Plus初凝时间和终凝时间分别为138分钟和210分钟,AH Plus分别为437分钟和849分钟(P < .05)。
  • Sealer Plus溶解度为0.21%,AH Plus为0.27%(P > .05)。
  • 两种封闭剂pH均无显著升高(P > .05)。

关键数值与推荐

  • 阻射性标准最低值为3 mm Al。
  • Sealer Plus流动性19.19 mm,AH Plus 19.81 mm(P > .05)。
  • Sealer Plus溶解度0.21%,AH Plus 0.27%(P > .05)。
  • Sealer Plus初凝138分钟、终凝210分钟;AH Plus初凝437分钟、终凝849分钟(P < .05)。

临床怎么用

  • Sealer Plus理化性能符合标准,凝固时间较短可能有利于临床操作。
  • 其阻射性虽低于AH Plus但仍满足最低要求,操作时需注意评估。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: The aim of this study was to evaluate some of the physicochemical properties of a new root canal sealer. METHODS: The sealers tested were Sealer Plus compared with AH Plus. For the radiopacity, flow, solubility, and fabrication of test specimens relative to setting times, the American National Standards Institute/American Dental Association No. 57 (2000) and International Organization for Standardization 6876 (2012) specifications were followed. To measure the initial and final setting times, the ASTM C266/2008 standard was used. pH was evaluated in the time intervals of 3, 24, 72, and 168 hours. Statistical tests were applied to the results obtained at a level of significance of 5%. RESULTS: The results demonstrated that the Sealer Plus sealer showed a lower radiopacity value than AH Plus sealer (P < .05); however, this was higher than the minimum value recommended by the specifications (ie, 3 mm Al). Relative to flow, the value for Sealer Plus was 19.19 mm and for AH Plus, 19.81 mm (P > .05). Sealer Plus presented initial and final setting times of 138 minutes and 210 minutes, respectively, whereas the values for AH Plus were 437 minutes and 849 minutes, respectively (P < .05). Relative to solubility, Sealer Plus presented 0.21% and AH Plus, 0.27% (P > .05). None of the sealers showed a significant increase in pH (P > .05). CONCLUSIONS: Sealer Plus sealer presented physicochemical properties in accordance with American National Standards Institute/American Dental Association (2000) No. 57 and International Organization for Standardization 6876 (2012) specifications.

来源:J Endod,查看原文。版权归原作者所有。

引用

  1. Vertuan GC, Duarte MAH, Moraes IG, et al. Evaluation of Physicochemical Properties of a New Root Canal Sealer. J Endod. 2017. PMID: 29254816. doi:10.1016/j.joen.2017.09.017

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。