微型CT与横截面法评估不同机械根管预备系统所致牙本质缺陷的比较
本研究比较微型CT与横截面法联合体视显微镜评估四种机械根管预备系统处理后牙本质缺陷的效果。结果显示横截面法观察到的缺陷数显著高于微型CT,且所有缺陷均为术前已存在,各预备系统均未导致新缺陷形成。
要点
- 横截面法观察到的牙本质缺陷数显著多于微型CT,术前术后均如此。
- 所有预备系统均未导致新的牙本质缺陷形成。
- 横截面法观察到的缺陷可能源于切片操作本身,而非根管预备。
核心结论
- 所有评估的机械根管预备系统均未导致新的牙本质缺陷形成。
- 体视显微镜下观察到的所有缺陷在预备前已存在,微型CT分析中则术前术后均未发现差异,提示新缺陷形成源于体视显微镜前的切片操作而非根管预备。
研究设计与样本
- 预备前后分别行微型CT扫描,随后在距根尖3、6、9 mm处横截面切片,体视显微镜下评估完全和不完全牙本质缺陷。
- 采用Kruskal-Wallis、Friedman和Wilcoxon非参数检验,显著性水平5%。
主要发现
- 横截面法联合体视显微镜观察到的缺陷总数在所有实验组中均显著高于微型CT观察到的缺陷数(P ≤ .05)。
- 术后识别的所有缺陷在相应术前已存在。
- 各预备系统间缺陷中位数无显著差异(P > .05),无论横截面法还是微型CT,在所有根水平均如此。
- 微型CT分析中,无论何种预备系统,预备前后缺陷中位数无显著差异(P > .05)。
临床怎么用
- 评估根管预备所致牙本质缺陷时,需注意横截面法可能引入切片相关伪影,微型CT或可更准确反映术前术后变化。
- 不同机械预备系统在牙本质缺陷形成方面未见显著差异,临床选择可综合考虑其他因素。
局限性
- 样本量有限(每组10个根),可能影响统计效能。
- 仅评估了下颌磨牙近中根,结果外推需谨慎。
- 横截面法本身可能造成缺陷,影响评估准确性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: The objective of this study was to compare the methods of micro-computed tomography (micro-CT) and cross-sectioning followed by stereomicroscopy in assessing dentinal defects after instrumentation with different mechanized systems. METHODS: Forty mesial roots of mandibular molars were scanned and divided into 4 groups (n = 10): Group R, Reciproc; Group PTN, ProTaper Next; Group WOG, WaveOne Gold; Group PDL, ProDesign Logic. After instrumentation, the roots were once again submitted to a micro-CT scan, and then sectioned at 3, 6, and 9 mm from the apex, and assessed for the presence of complete and incomplete dentinal defects under a stereomicroscope. The nonparametric Kruskal-Wallis, Friedman, and Wilcoxon tests were used in the statistical analysis. The study used a significance level of 5%. RESULTS: The total number of defects observed by cross-sectioning followed by stereomicroscopy was significantly higher than that observed by micro-CT, in all of the experimental groups (P ≤ .05). All of the defects identified in the postoperative period were already present in the corresponding preoperative period. There was no significant difference among the instrumentation systems as to the median numbers of defects, for either cross-sectioning followed by stereomicroscopy or micro-CT, at all the root levels (P > .05). In the micro-CT analysis, no significant difference was found between the median numbers of pre- and postinstrumentation defects, regardless of the instrumentation system (P > .05). CONCLUSION: None of the evaluated instrumentation systems led to the formation of new dentin defects. All of the defects identified in the stereomicroscopic analysis were already present before instrumentation, or were absent at both time points in the micro-CT analysis, indicating that the formation of new defects resulted from the sectioning procedure performed before stereomicroscopy and not from instrumentation.
引用
- Stringheta CP, Pelegrine RA, Kato AS, et al. Micro-computed Tomography versus the Cross-sectioning Method to Evaluate Dentin Defects Induced by Different Mechanized Instrumentation Techniques. J Endod. 2017. PMID: 29033087. doi:10.1016/j.joen.2017.07.015
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。