文献速递牙体牙髓病

HyFlex CM与HyFlex EDM镍钛锉根管预备后表面形貌变化的三维光学轮廓仪比较研究

Comparison of Alterations in the Surface Topographies of HyFlex CM and HyFlex EDM Nickel-titanium Files after Root Canal Preparation: A Three-dimensional Optical Profilometry Study.
PubMed 文献 · J Endod · 2017-10-09

本研究用三维光学轮廓仪比较了HyFlex CM与HyFlex EDM镍钛锉在预备重度弯曲磨牙根管前后的表面形貌变化。每组各8支锉预备32个弯曲度50°–70°的根管,结果显示HyFlex EDM组使用后出现裂纹和微腔,但粗糙度参数在预备前后无统计学显著增加(P > .5);HyFlex CM组仅见轻微表面变形,但粗糙度值显著增加(P < .05)。

要点

  • HyFlex EDM锉使用后出现裂纹和微腔,但粗糙度参数无显著增加。
  • HyFlex CM锉使用后仅见轻微表面变形,但粗糙度值显著增加。
  • 预备前后HyFlex EDM组的粗糙度参数均显著高于HyFlex CM组(P < .05)。

核心结论

  • 在重度弯曲根管预备后,HyFlex CM锉的表面变化显著大于HyFlex EDM锉。

研究设计与样本

  • 体外研究纳入8支HyFlex CM(25/.08)和8支HyFlex EDM(25/.08)锉。
  • 共预备64个弯曲度50°–70°的重度弯曲磨牙根管,每组32个。
  • 使用三维光学轮廓仪在预备前后进行定量与定性分析,采用Student t检验(5%显著性水平,SPSS 21.0)。

主要发现

  • 定性评估显示HyFlex EDM组使用后存在裂纹和微腔,HyFlex CM组仅见轻微表面变形。
  • 预备前后HyFlex EDM组的平均粗糙度、均方根粗糙度和峰谷高度值均显著高于HyFlex CM组(P < .05)。
  • HyFlex CM组预备后表面粗糙度值显著增加(P < .05)。
  • HyFlex EDM组预备后粗糙度增加无统计学显著性(P > .5)。

临床怎么用

  • 在重度弯曲根管预备场景下,HyFlex CM锉的表面粗糙度增加更明显,需关注其表面完整性。

局限性

  • 结论受本研究局限性约束,原文未具体说明局限性内容。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: The aims of the present study were to examine the surface topographies of intact HyFlex CM and HyFlex EDM nickel-titanium files and to compare alterations in the surface topographies of these files after root canal preparation of severely curved canals of molar teeth. METHODS: Eight HyFlex CM (25/.08) and 8 HyFlex EDM (25/.08) files were included in the present study. In total, 64 severely curved canals of molar teeth, with curvature angles ranging between 50° and 70°, were prepared with HyFlex CM and EDM (n = 32 in each group). Quantitative and qualitative analyses of the files' surface deformation were performed by using three-dimensional optical profilometry before and after root canal preparation. The data were analyzed with the Student t test at the 5% significant level by using SPSS 21.0 software. RESULTS: In the HyFlex EDM group, the qualitative evaluation revealed the presence of cracks and microcavities after use of the file for root canal preparation, whereas only minor surface deformation was observed in the HyFlex CM group. The average roughness, root mean square roughness, and peak to valley height values of the HyFlex EDM group were significantly higher than those of the HyFlex CM group before and after root canal preparation (P < .05). The surface roughness values were statistically significantly increased in the HyFlex CM group after root canal preparation (P < .05). In contrast, the increase in the HyFlex EDM group was not statistically significant (P > .5). CONCLUSIONS: Within the limitations of the present study, the HyFlex CM files showed significantly higher surface alterations compared with the HyFlex EDM files after the preparation of severely curved root canals.

来源:J Endod,查看原文。版权归原作者所有。

引用

  1. Uslu G, Özyürek T, Yılmaz K, et al. Comparison of Alterations in the Surface Topographies of HyFlex CM and HyFlex EDM Nickel-titanium Files after Root Canal Preparation: A Three-dimensional Optical Profilometry Study. J Endod. 2017. PMID: 29032817. doi:10.1016/j.joen.2017.05.023

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。