旋转与往复运动根管预备后根尖孔变形的扫描电镜研究
结果显示两种运动方式在根尖孔处或超过根尖孔1 mm预备均导致根尖孔变形(P < .05),与运动方式无关。
要点
- 旋转或往复运动在根尖孔处或超过根尖孔1 mm预备均致根尖孔变形。
- 两种运动方式对根尖孔变形的差异无统计学意义。
- 弯曲30–65°的磨牙近中颊根在根尖区预备时需注意根尖孔形态改变。
核心结论
- 在根尖孔处或超过根尖孔1 mm进行根管预备均会导致根尖孔变形,与所用运动方式无关。
研究设计与样本
- 牙根分为旋转运动组(n = 30)和往复运动组(n = 30),每组分别在根尖孔处和超过根尖孔1 mm两个工作长度下预备。
- 预备后再次扫描电镜拍摄,由3名独立评估者在不知运动方式和预备长度的情况下与基线图像比较评估根尖孔变形。
- 统计分析采用Pearson相关检验和Kruskal-Wallis检验(Dunn法),显著性水平P < .05。
主要发现
- Pearson相关检验显示评估者间一致性良好。
- 两种运动方式在根尖孔处和超过根尖孔1 mm预备后均观察到根尖孔变形(P < .05)。
关键数值与推荐
- 根尖孔变形评估以预备前扫描电镜基线图像为对照。
- 两种运动方式在根尖孔处或超过根尖孔1 mm预备后根尖孔变形均有统计学意义(P < .05)。
临床怎么用
- 临床在弯曲30–65°磨牙近中颊根行根尖区预备时,应预期根尖孔可能变形,无论选用旋转或往复运动。
局限性
- 结论受本研究局限性约束,原文未具体列出局限性内容。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: The aim of this study was to evaluate, under scanning electronic microscopy, the morphological aspect of apical foramen after root canal instrumentation with rotary and reciprocating kinematics at 2 different working length determinations. METHODOLOGY: Sixty mesiobuccal roots of mandibular and maxillary molars presenting with curvature ranging from 30 to 65° were used in this study. The roots were initially scanned with a scanning electronic microscope under ×50 magnification. Roots were divided into 2 different groups (n = 30): group 1 instrumented with rotary kinematics, and group 2 instrumented with reciprocating kinematics. Both groups were instrumented at 2 different working lengths: at the apex and 1 mm beyond the apex. The roots were scanned after the instrumentation at the apex and again after further instrumentation 1 mm beyond the apex. The photomicrographs obtained were assigned to 3 independent evaluators for foraminal deformation assessment through comparison with baseline images. Evaluators were masked with regard to the kinematics and working length used. The Pearson correlation test and Kruskal-Wallis test (method of Dunn) were used for statistical analysis (P < .05). RESULTS: The Pearson Correlation test showed good agreement among evaluators. Foraminal deformation was observed in instrumentation at the apex and 1 mm beyond the apex with both kinematics (P < .05). CONCLUSIONS: Within the limitations of this study, it can be concluded that root canal instrumentation at the apex or 1 mm beyond the apex promoted deformation of the major foramen, regardless of the kinematics.
引用
- Silva Santos AM, Portela FMSF, Coelho MS, et al. Foraminal Deformation after Foraminal Enlargement with Rotary and Reciprocating Kinematics: A Scanning Electronic Microscopy Study. J Endod. 2017. PMID: 29033083. doi:10.1016/j.joen.2017.08.013
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。