文献速递牙体牙髓病

显微CT伪影减少工具对牙髓研究图像的影响

Influence of Artifact Reduction Tools in Micro-computed Tomography Images for Endodontic Research.
PubMed 文献 · J Endod · 2017-10-21

本研究评估显微CT图像重建中伪影减少工具(环形伪影减少RAR与线束硬化伪影减少BAR)对牙髓研究结果的影响。

要点

  • BAR协议间主观偏好无差异(P = .91),RAR协议间亦无差异(P = .80)。
  • 所有协议间根管体积(P = .999)和表面积(P = .972)无统计学显著差异。
  • 伪影减少工具可按观察者视觉偏好选用,不影响根管体积与表面积的客观分析。

核心结论

  • 评估根管体积和根管表面积时,显微CT图像应用的伪影减少工具可按观察者视觉偏好使用,不影响客观图像分析。

主要发现

  • BAR协议间无主观偏好(P = .91),RAR协议间亦无主观偏好(P = .80)。
  • 所有协议间根管体积无统计学显著差异(P = .999),根管表面积无统计学显著差异(P = .972)。

关键数值与推荐

  • 主观偏好采用χ2检验,客观分析采用方差分析比较根管体积和表面积,观察者内与观察者间可重复性用加权kappa检验计算。

临床怎么用

  • 在牙髓研究中评估根管体积和表面积时,可根据观察者视觉偏好选择伪影减少工具协议,无需担心影响客观测量结果。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: Micro-computed tomography (μCT) is an imaging modality of growing application in endodontic research because of its nondestructive technology that enables visualization at the micrometer level. In the presence of high-density material, images acquired with μCT may present artifacts. Thus, the aim of this study was to evaluate subjectively and objectively the influence of artifact reduction tools available for μCT image reconstruction to determine whether their use can influence endodontic research outcomes. METHODS: Ten teeth were scanned in a μCT device, and these images were reconstructed by applying 13 protocols of artifact reduction tools, combining ring artifact reduction (RAR) and beam-hardening artifact reduction (BAR). Images were assessed subjectively (observer's preference) and objectively (root canal surface area and volume). Observer's preference for RAR and BAR protocols was tested by χ2. Analysis of variance was used to compare volumes and surface area of root canals on different protocols. Intraobserver and interobserver reproducibility was calculated by the weighted kappa test. RESULTS: There was no preference for a particular protocol for BAR (P = .91) or RAR (P = .80). There were no statistically significant differences for volume (P = .999) or surface area (P = .972) of root canals for all protocols. CONCLUSIONS: To evaluate root canal volume and root canal surface area, artifact reduction tools applied to μCT images can be used according to the observer's visual preference without influence on objective image analysis.

来源:J Endod,查看原文。版权归原作者所有。

引用

  1. Queiroz PM, Rovaris K, Gaêta-Araujo H, et al. Influence of Artifact Reduction Tools in Micro-computed Tomography Images for Endodontic Research. J Endod. 2017. PMID: 29033091. doi:10.1016/j.joen.2017.07.024

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。