文献速递牙体牙髓病

硅酮/生物活性玻璃与硅酸钙基根管封闭剂的理化性能及体积变化

Physicochemical Properties and Volumetric Change of Silicone/Bioactive Glass and Calcium Silicate-based Endodontic Sealers.
PubMed 文献 · J Endod · 2017-10-09

本研究比较硅酮-牙胶-生物活性玻璃基封闭剂GuttaFlow Bioseal(GFB)、硅酸钙基封闭剂TotalFill BC Sealer(TFBC)与AH Plus的凝固时间、阻射性、pH、流动性、溶解度和体积变化。TFBC的pH和溶解度最高,GFB凝固时间最短且阻射性与流动性最低,3种封闭剂体积变化相似,GFB理化性能良好。

要点

  • TFBC在3种封闭剂中pH与溶解度最高,体积变化与GFB、AH Plus相似。
  • GFB凝固时间最短,阻射性和流动性最低,整体理化性能良好。
  • 微型CT可用于补充评估根管封闭剂的体积变化。

核心结论

  • TFBC的pH和溶解度最高,但体积变化与GFB及AH Plus相似;GFB表现出适当的理化性能;微型CT可补充根管封闭剂的理化分析。

研究设计与样本

  • 体外研究,比较GFB、TFBC与AH Plus 3种根管封闭剂;按ISO 6876标准评估凝固时间与流动性。
  • pH于1、3、7、14、21、28天评估;阻射性以铝毫米数行X线分析评估。
  • 溶解度以蒸馏水浸泡7天和30天后的质量损失百分比评估;体积变化用微型CT在丙烯酸树脂中3 mm深、1 mm直径的腔内评估,于凝固后及浸泡7天、30天后观察。
  • 数据采用方差分析和Tukey检验(P < .05)。

主要发现

  • TFBC的pH和溶解度最高。
  • GFB凝固时间最短,阻射性和流动性值最低。
  • 3种封闭剂在两个时间间隔的体积变化相似。

关键数值与推荐

  • 凝固时间与流动性按ISO 6876标准评估。
  • pH评估时间点为1、3、7、14、21、28天。
  • 溶解度于浸泡蒸馏水7天和30天后以质量损失百分比评估。
  • 体积变化用微型CT在3 mm深、1 mm直径的腔内于凝固后及浸泡7天、30天后评估。
  • 统计分析采用方差分析和Tukey检验,P < .05。

临床怎么用

  • 选择封闭剂时可参考其凝固时间、阻射性与流动性差异,GFB凝固快但阻射性低。
  • 关注高pH与高溶解度封闭剂(TFBC)对根管环境的潜在影响。
  • 可用微型CT评估封闭剂在根管内的体积变化。

局限性

  • 原文未报告

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: This study evaluated setting time (ST), radiopacity, pH, flow, solubility, and volumetric change (VC) of a silicone, gutta-percha, and bioactive glass-based sealer, GuttaFlow Bioseal (GFB), and a calcium silicate-based sealer, TotalFill BC Sealer (TFBC), in comparison with AH Plus. METHODS: ST and flow were evaluated in accordance with the ISO 6876 Standard. pH was evaluated after different time intervals (1, 3, 7, 14, 21, and 28 days). Radiopacity was evaluated by radiographic analysis in millimeters of aluminum. Solubility was evaluated by means of mass loss (%) after 7 and 30 days of immersion in distilled water. VC was evaluated by micro-computed tomography, by using cavities 3 mm deep and 1 mm in diameter in acrylic resin, filled with the materials. The materials were evaluated after setting and after 7 and 30 days of immersion in distilled water. The data were submitted to analysis of variance and Tukey statistical tests (P < .05). RESULTS: TFBC demonstrated the highest pH and solubility. GFB had the shortest ST, and lowest radiopacity and flow values. VC was similar for the sealers in both time intervals. CONCLUSIONS: TFBC presented the highest pH and solubility, but showed similar VC to GFB and AH Plus. GFB showed proper physicochemical properties. Micro-computed tomography complements the physicochemical analysis of endodontic sealers.

来源:J Endod,查看原文。版权归原作者所有。

引用

  1. Tanomaru-Filho M, Torres FFE, Chávez-Andrade GM, et al. Physicochemical Properties and Volumetric Change of Silicone/Bioactive Glass and Calcium Silicate-based Endodontic Sealers. J Endod. 2017. PMID: 29032816. doi:10.1016/j.joen.2017.07.005

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。