三种器械系统预备卵形根管的清洁与成形:微CT与组织学关联研究
研究用微CT与组织学关联分析,评估SAF、TRUShape和XP-endo Shaper在33颗新鲜拔除活髓下颌磨牙卵形远中根管中的清洁与成形能力。结果显示在根尖4mm区段SAF未预备面积显著少于XP-endo Shaper(P < .05),全根管长度及未预备壁清洁能力三组间无显著差异(P > .05),且均未100%预备根管壁。
要点
- 根尖4mm区段SAF未预备面积显著少于XP-endo Shaper(P < .05)
- 全根管长度三组未预备面积及未预备壁清洁能力无显著差异(P > .05)
- 三种系统均未100%预备根管壁,清洁能力相似
核心结论
- 三种器械系统在未预备面积上无显著差异,仅根尖4mm区段SAF与XP-endo Shaper比较有差异。
- 三种系统均未100%预备根管壁,清洁能力相似。
研究设计与样本
- 采用微CT与组织学关联分析方法,对33颗新鲜拔除活髓下颌磨牙的卵形远中根管进行扫描筛选。
- 按解剖相似性匹配后分为SAF、TRUShape和XP-endo Shaper三组,冲洗液为加热至37°C的5.25%次氯酸钠。
- 再次微CT扫描后识别并测量未预备表面积,并对每个根三分之一区域进行组织学评估牙髓残留量。
主要发现
- 根尖4mm区段SAF未预备面积显著少于XP-endo Shaper(P < .05),其他比较无显著差异(P > .05)。
- 全根管长度分析显示三种系统间无统计学显著差异(P > .05)。
- 三种系统在清洁未预备壁方面无显著差异(P > .05)。
临床怎么用
- 对于卵形根管,三种系统均无法完全预备根管壁,临床需注意未预备区域的清洁。
- 在根尖4mm区段,SAF可能较XP-endo Shaper覆盖更多根管壁面积。
局限性
- 研究为体外实验,样本为33颗新鲜拔除活髓下颌磨牙,结果外推需谨慎。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: The present study evaluated the cleaning and shaping ability of 3 instrumentation systems in oval canals of extracted vital teeth using a correlative analytic approach. METHODS: Oval distal canals from 33 freshly extracted mandibular molars with pulp vitality were scanned by micro-computed tomographic (micro-CT) imaging for sample selection. Specimens matched by anatomic similarities were distributed into 3 experimental groups according to the instrument system to be evaluated: the Self-Adjusting File (SAF; ReDentNOVA, Ra'anana, Israel), TRUShape (Dentsply Sirona, Tulsa, OK), and XP-endo Shaper (FKG Dentaire, La Chaux-de-Fonds, Switzerland). The irrigant was 5.25% sodium hypochlorite heated at 37°C. After rescanning with micro-CT imaging, the unprepared surface areas were identified, measured, and then histologically evaluated for the amount of pulp remnants in each root third. RESULTS: When the apical 4-mm canal segment was evaluated, the SAF exhibited significantly less unprepared areas than the XP-endo Shaper (P < .05), and there were no significant differences for the other comparisons (P > .05). Analysis of the full canal length showed no statistically significant differences between the 3 tested systems (P > .05). Likewise, the tested systems did not differ significantly in cleaning the unprepared walls (P > .05). CONCLUSIONS: There was no significant difference in the amount of unprepared surface areas between the 3 instrument systems, except for the comparison between the SAF and XP-endo Shaper in the apical 4-mm segment. None of them prepared 100% of the root canal walls. The cleaning ability of the 3 systems was similar.
引用
- Lacerda MFLS, Marceliano-Alves MF, Pérez AR, et al. Cleaning and Shaping Oval Canals with 3 Instrumentation Systems: A Correlative Micro-computed Tomographic and Histologic Study. J Endod. 2017. PMID: 28951035. doi:10.1016/j.joen.2017.06.032
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。