根管牙本质含水量影响micro-CT微裂纹检测
研究选取含或不含裂纹的10个牙根,在6种不同湿度条件下用10.5 μm高分辨率micro-CT扫描,由5名校准盲法观察者评估牙本质微裂纹。结果显示湿储存后几乎观察不到裂纹,干燥2小时后裂纹显著增加,24小时干燥后又显著多于2小时;结论认为微-CT检测微裂纹受牙本质含水量影响,应在干燥标本上扫描。
要点
- 湿储存状态下micro-CT几乎检测不到牙本质微裂纹
- 干燥2小时后微裂纹检出显著增加,24小时干燥后进一步增加
- 建议micro-CT评估牙本质缺陷时对标本进行干燥处理
核心结论
- 牙本质含水量影响micro-CT对微裂纹的检测,扫描应在干燥标本上进行以可靠识别牙本质缺陷。
- 干燥至24小时并未导致新裂纹形成。
研究设计与样本
- 选取含或不含裂纹的牙根共10个(每组n=5),在6种湿度条件下各扫描一次。
- 使用micro-CT以10.5 μm高分辨率扫描,按1 mm间隔获取共708张横截面图像。
- 由5名校准盲法观察者评估两次,采用纵向数据非参数方差分析(P < 0.05)。
主要发现
- 观察者自身一致率为92%–98%,观察者间一致率为81%和83%。
- 各湿储存组之间及两个2小时干燥组之间均无显著差异(P > 0.05)。
- 湿储存后几乎观察不到裂纹,2小时干燥后裂纹显著增加(P < 0.001)。
- 24小时干燥后检出的微裂纹显著多于2小时干燥(P < 0.004)。
关键数值与推荐
- 扫描条件依次为:湿储存30天后、干燥2小时后、湿储存48小时后、干燥24小时后、湿储存48小时后、干燥2小时后。
- 横截面图像间隔为1 mm,总图像数n=708。
- micro-CT扫描分辨率为10.5 μm。
临床怎么用
- 用micro-CT评估根管牙本质微裂纹时,应先将标本干燥再扫描以提高检出可靠性。
- 解读湿储存标本的micro-CT结果时需考虑含水量可能掩盖微裂纹。
局限性
- 样本量较小,含与不含裂纹的牙根各n=5。
- 研究为离体牙根实验,结论外推至临床需谨慎。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIM: To evaluate the effect of moisture content in root canal dentine on detection of microcracks using micro-computed tomography. METHODOLOGY: Ten roots with and without craze lines or cracks (each n = 5) were selected and scanned six times with different moisture conditions of root dentine using a micro-CT scanner at a high resolution of 10.5 μm. Scanning conditions were as follows: (i) after 30-day wet storage, (ii) after 2-h dry time, (iii) after 48-h wet storage, (iv) after 24-h dry time, (v) after 48-h wet storage, (vi) after 2-h dry time. From each scan, cross-sectional images were obtained at intervals of 1 mm (total n = 708) and evaluated for the presence of dentinal microcracks twice by five calibrated blinded observers. Statistical analysis was performed by nonparametric analysis of variance for longitudinal data (P < 0.05). RESULTS: Intra-rater percentage agreement ranged between 92% and 98%, whereas inter-rater percentage agreement was 81% and 83%, respectively. No significant differences between all wet groups as well as between both groups with 2-h dry time were detected (P > 0.05). Almost no cracks were observed after wet storage with a significant increase of cracks after 2-h dry time (P < 0.001). Significantly more microcracks were identified after 24 h than after 2-h dry time (P < 0.004). CONCLUSIONS: Moisture content of dentine influenced detection of microcracks when evaluated using micro-CT. Scanning should be performed on dried specimens to allow reliable identification of dentinal defects. Formation of new cracks during dry periods up to 24 h was disproved.
引用
- Rödig T, Müller C, Hoch M, et al. Moisture content of root canal dentine affects detection of microcracks using micro-computed tomography. Int Endod J. 2017. PMID: 28857192. doi:10.1111/iej.12850
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。